Liebert iCOM-S - Improve Data Center Design and Efficiency

Emerson Network Power > United States > Products > By Type > Thermal Management > Environmental Monitoring > Remote Monitoring > Liebert iCOM-S Thermal Sys​tem Supervisory Control

Liebert iCOM-S Thermal Sys​tem Supervisory Control

Optimize the Entire ​Cooling System for Higher Efficiency.

​​
Manage and control your entire data center cooling system for up to 50% higher efficiency, improved protection and greater productivity. Liebert iCOM-S provides a single point for managing your entire cooling infrastructure and gaining quick access to actionable data, system diagnostics and trending.
Overview
The Liebert iCOM-S system control is a single point for centralizing data from sensors and cooling units, unlocking the benefits of machine-to-machine communications to harmonize and optimize thermal system performance across the data center. This prevents units from working at cross-purposes and allows the system as a whole to adapt to changes in data center capacities as efficiently as possible to improve availability and energy efficiency. It operates on an all-in-one, touch screen computer that mounts virtually anywhere, providing quick access to actionable data and system diagnostics and trending.
Features
​​
  • Available as an upgrade to existing Liebert equipment
  • Single point for accessing data from all sensors and cooling units
  • Teamwork modes to harmonize the operation of multiple cooling units
  • Pre-configured for operation with Liebert iCOM unit controls
  • Pre-configured for sensor bonding and can detect and configure up to 4,800 wireless sensors, reducing sensor installation costs by up to 50 percent
  • Multiple zone support for configuration of different types of cooling spaces within the data center
  • Large format touch-screen simplifies configuration and access to functions and reports
​​
Benefits

Higher Efficiency

  • When used with Liebert iCOM unit controls, can reduce cooling energy usage by up to 50%
  • Advanced algorithms and machine-to-machine communications optimize the performance of thermal units across the data center
  • Automatic adjustments to airflow and temperature to optimize efficiency and ensure protection as data center capacity and environmental conditions change
  • Teamwork mode eliminates units from operating in conflict to improve efficiency and protection
  • Automatic de-activation of un-needed units during low-load conditions

Greater Protection

  • View operating properties of all cooling units
  • Set and monitor events thresholds and alarms
  • Automate Lead/Lag, Cascade and Supply Compensation
  • Monitor sensor temperatures, battery condition and signal strength
  • Ensure wireless sensor integrity, security and redundancy
  • User authorizations for security and on-board change log

Insight for Action

  • Tracks key thermal metrics and visually displays urgent issues
  • Historical analysis of unit and IT temperatures to assist with infrastructure changes and to view performance
  • Reduces installation costs by up to 20 percent by reducing
  • requirements for integration with other systems and by streamlining configuration and setup
  • Multiple views - device, room, site levels
  • Create new favorite trend metrics and overlay multiple view on one screen
Technical Specifications
​​
  • 22” 1920 x 1080 (16:9) HD capacitive multi-touch screen, with mounting hardware
  • 2 x USB 3.0 Ports
  • 1 x HDMI output
  • 48-port network switch
  • 4-port router
  • Connects directly into Liebert iCOM control units machine-to-machine network
  • Power connection for up to 16 daisy-chained gateways (4,800 wireless sensors)
  • Room editor to customize floor plan and layout
Expansion Options
  • 100 wireless modules with 3 sensors per module
  • Optional wired sensors direct to units for backup
  • Additional network switches for additional unit connectivity

Up to 50% Higher Efficiency

Watch the Video

$171,690 in Annual Energy Savings

View the Infographic

20% Lower Installation Costs

Watch the Video