The ASCO Series 386 Non-Automatic Power Transfer Switch is generally used in applications where operating personnel are available and the load is not an emergency type requiring automatic transfer of power. The power-switching mechanism and controller of ASCO Series 386 is the same hardware used on the highly reliable ASCO Series 300 transfer switches. As a standard, the ASCO Series 386 is furnished with a momentary-type selector switch to initiate transfer and retransfer. It can also be arranged for remote control via ASCO's communications products.

Electrical Features: 

  • Listed under UL 1008, CS certified:
    1. UL Listed through 480 VAC
    2. CSA certified through 600 VAC
  • Door-mounted selector switch for local, manually initiated electrical control
  • Sizes for 30 through 3000 amps
  • Available t600 VAC, 50 or 60 HZ
  • Rated for all classes of load transfer
  • 100% tungsten load ratings through 400 amps
  • Designed for emergency and standby applications
  • Same withstand and close-on rating as Series 300

Standard Selectable Control Features:

  • Inphase monitor ttransfer motor loads between live sources, without any intentional off time, tprevent inrush currents from exceeding normal starting levels
  • Selective load disconnected, double-throw contact toperate at an adjustable 0 t20 second time delay prior ttransfer and reset 0 t20 seconds after transfer
  • High/Low nominal voltage setting allows user tadjust for source low reduced voltage conditions in remote areas
  • 60 Hz or 50 Hz selection switch
  • Single/Three-phase selection Switch

Control Features:

  • Switch position indicating signal lights
  • One auxiliary contact, closed when transfer switch is connected tnormal and one closed on emergency, standard feature 14A/14B 
Features

 

  • 6Q Key-operated, momentary source selector switch furnished instead of the standard selector switch.
  • 9C, 9D Source availability lights to provide operator with a local indication of power source availability.
  • Accessory 14AA/14BA auxiliary contacts to indicate position of main contacts. Two (2) for normal position and two (2) for emergency position (one set is standard).
  • 72A Communication interface module (RS-485) to allow local or remote communications with ASCO PowerQuest® or SITEWEBTM communications products.
  • 72E Connectivity Module 5150 is used to bring several different serial devices that communicate at different baud rates and with different protocols to a common Ethernet media.
  • Special enclosures (Specify by appropriate code in catalog number):
    • Type 3R: Rain tight
    • Type 4: Weatherproof
    • Type 12: Oil Tight
     
Options