| 2C |
An extended time delay on engine starting. Adjustable from 0 to 60 min in 1 second steps. Factory set at 5 minutes. |
| 1G |
Similar to accessory 2C except using 24 volt DC external input signal. 7000 Series controller remains active when both power sources are de-energized. |
|
|
| 6C |
Reset switch for manual retransfer to normal with automatic retransfer in the event of emergency source failure. |
| 6D |
Selector switch for automatic/manual retransfer to normal. Automatic bypass if emergency fails. |
|
|
| 12 |
Three position engine control selector switch. Positions: 1 - Stop 2 - Automatic 3 - Engine Test |
| Note: |
The addition of accessory 12 requires the product to be labeled "Non-Automatic Transfer Switch" as defined in UL1008. Engine controls containing engine stop positions should be located at the engine generator. (Consult ASCO for application assistance). |
|
|
| 14A/14B |
Additional auxiliary contact sets to indicate switch position. Two sets are standard. Specify total number of sets if more are required. |
| 18B |
Two-pole, double-throw contacts operate when emergency source voltage is present at transfer switch terminals. |
| 18G |
Two-pole, double-throw contacts operate when normal source voltage is present at transfer switch terminals. |
| 99 |
Push-to-Test feature on all pilot light indicators. |
|
|
| 30A |
Load-shedding circuit initiated by opening of a customer-supplied contact. |
| 30B |
Load-shedding circuit initiated by removal of customer-supplied control voltage. (Specify voltage). |
| 31Z |
Selective load disconnect control contacts (two provided) which operate with time delay prior to and/or after load transfer and retransfer. |
| 43R |
Terminal block for all customer control connections on 30-150 amp only (standard on all other sizes). |
|
|
|
Solid neutral, with fully-rated terminals. (AL-CU) UL Listed. |
|
Conventional neutral switching pole. |
|
Overlapping neutral transfer contacts. Allows for proper ground-fault sensing and avoids generator voltage transients during transfer. |
| Notes: |
Specify neutral option in catalog number, see page 16 for instructions. |
|
|
| 37B |
Six foot (6') extension harness to increase distance between transfer switch and control panel on open-type units. |
|
|
| 23B |
Three phase ammeter with selector switch (with current transformers and shorting blocks). |
| 24B |
Three phase voltmeter with selector switch. |
| Notes: |
Refer to ASCO 7000 Series Data Monitor which provides voltage, frequency and power monitoring. |
|
|
| 72A |
Serial communication module for remote communications to ASCO Power Quest products. |
|
|
| 73AC1 |
Normal source protection. (3Ø, 4wire WYE) |
| 73AC2 |
Emergency source protection. (3Ø, 4wire WYE) |
| 73AC3 |
Load side protection. (3Ø, 4wire WYE) |
| Notes: |
Other distribution voltages available (Contact ASCO). |
|
|
| 111A |
Generator-to-Generator for Standby Applications |
| 111B |
Generator-to-Generator for Prime Power Applications |
|
|
| 14A1 |
Auxiliary contact to close in Bypass to Normal position. |
| 14B1 |
Auxiliary contact to close in Bypass to Emergency position. |
| 14T |
Auxiliary contact to close when transfer switch is in Automatic position. |
| 14U |
Auxiliary contact to close when transfer switch is in Isolate position. |
| 14V |
Auxiliary; contact to close when transfer switch is in Open position. |
| 14W |
Auxiliary; contact to close when transfer switch is in Test position. |
|
|
| 82B |
Transfer switch lifting yoke to facilitate the removal of the transfer switch from the drawout carriage. |
| 82C |
Automatic shutters to provide isolation of bus stabs. |
|
|
| Notes: |
An externally operable quick-make, quick-break (QMQB), manual handle is available on some 7000 Series product configurations. (Consult ASCO for guidance). |
| 125 |
Factory qualified seismic rating to IBC2003 code. Contact Customer Care for information |