​A Revenue-grade Energy Meter with Advanced Power Quality Analytics.

The device continuously records waveforms at high-speed and identifies transients, sags/swells and harmonics. Installation examples include generators, utility mains, transfer switches, UPS systems, paralleling gear, TVSS, PDUs, and critical power distribution switchboards.​
Product Downloads
Download
 
  Manuals

Warranties
​​​​
Overview
The ASCO Power Quality Meter helps reduce energy costs while increasing reliability and decreasing infrastructure cost. The device continuously records waveforms at high-speed and identifies transients, sags/swells and harmonics. Installation examples include generators, utility mains, transfer switches, UPS systems, paralleling gear, TVSS, PDUs, and critical power distribution switchboards.​
Features
​​​​Features
  • ​Continuous Waveform Recording (CWR) Technology provides complete data for accurate power quality analysis
  • Millisecond time-stamp accuracy and synchronization for precise sequence of events analysis
  • CWR Technology eliminates the need to setup any thresholds, triggers and events
  • 25 Second Power-ride through capability allows uninterrupted data recording during power outage
  • Automatic measurement compensation  based on internal temperature monitoring ensures maximum accuracy
  • Automated reports are generated for prescheduled periods and exported in COMTRADE and PQDIF (event reports), PDF, EXCEL, HTML and TXT (all other reports)
  • Provides compliance testing to parameters in accordance with EN50160 and IEC 61000-4-15 / IEC 61000-4-30
  • Real time monitoring with integrated web pages and alerts by email notifications
​​​ 5410 Entry-Level​​ 5450 Advanced 5490 Mission Critical​
7000 Series Transfer Switch Accessories​ ​Acc. 140L ​Acc. 140LS ​Acc. 140LX
​7000 Series Bypass-Isolation Transfer Switch Accessories ​N/A ​Acc. 140SB ​Acc. 140XB
​7000 Series Power Control Accessories
✔​
Standalone Enclosure/Loose Units​ ​​
 ​​​​​
Ordering Information
​​​​Features 5410 Entry-Level​​ 5450 Advanced 5490 Mission Critical​
Maximum Voltage Sampling Rateper Cycle​ 256 512 1024​
Voltage Harmonics Up-to​ ​127th 255th​​ ​511th
Analog to Digital Converter​ ​16/20 bit ​16/20 bit 16/20 bit​
Internal Memory​ ​128MB 4GB​​​ ​16GB
Transient Detection 50Hz / 60Hz​ 78.1/65.1 µs​ 39/32.5 µs​ 19.5/16.3 µs​
Voltage Ride-Through on Power Loss (up to )​​ 10 seconds​ ​25 seconds ​25 seconds​
​Measurement During Overloading x2​ x10​ x10​
Ethernet Ports​ ​1 ​2
NTP Time Synchronization​ Yes​ ​Yes ​Yes
​PoE out to 5010 -​ Yes​ Yes​
​IRIG-B Port(s)/ GPS RS232 Port(s) -​ 1​ ​2
​Digital Inputs ​- ​8 ​16
​Digital Outputs -​ 4​ ​8
Analog Inputs​ ​- ​4 8​
​Analog Outputs ​-​ ​4 8​
​Form "C" Relay Contacts - 3 ​6
​Dimensions 6.87" x 9.12" x 5.41"
6.87" x 9.12" x 6.76" 6.87" x 9.12" x 8.07"
Weight 5.41lbs ​6.40lbs 7.10lbs
 
​​​​​General
​​​Real Time Measurements
Voltage/Current Per Phase and Neutral, Average, Unbalance
Power​ Real, Reactive, Apparent, Power Factor, Frequency
Energy: Bi-directional, Total, Import, Export, Net
Demand Block, Rolling Block, Thermal, Predicted
Temperature Sensor
Internal PSU​ ​Informative
​Internal DSP Measurement Compensation​
External -40C to 99C ​
Time​​​
Syncronization Device Accuracy
​GPS 100-200 µs
IRIG-B
100-200 µs
DCF-77 +/- 15 ms
​SNTP Server 50-100 µs
​Environmental
​Operating Temp
-4F to 158F (-20C to 70C)
Storage
-40F to 185F (-40C to 185C)
Pollution Degree​ 2​
Insulation Category​ ​II
Humidity​ Max 95% non-condensing​​
 ​​​​​  ​​​​
​​​I/O
Analog Inputs​
4-20mA (continuous DC), 25 ohm, 270V
Analog Outputs​ 4-20mA (continuous DC), 0.1% Accuracy (10 bit D to A resolution)
Digital Inputs Range: 0-220Vdc Triggers: Edge, Level, Debounce
Digital Outputs 100V Max Voltage Edge, Level, Trigger, KYZ Pulse Out
Relay 277VAC Max Voltage, 5A/250VAC, 10A/110VAC, 5A/30VDC, 10ms Max reaction time, 4 ms max drop-out time, 50mohm output resistance
 ​​​​​
Sensing Input ​​​​
​​​Voltage Inputs
Nominal Full Scale
1KV
Maximum Peak
8KV
Input Impedance 3MΩ
Uncertainty 0.1% of Nominal
Current Input​ ​
​Nominal Full Scale 5A​
​Maximum Full Scale 50A​
​Load/Burden 0.07VA @ 100A, 0.0001VA @ 5A​
​Phase shift 0.42 degrees @ 3A, 0.17 degrees @ 5A​
​Uncertainty 0.1% of Nominal​
Frequency​​ ​
​Range 42.5Hz to 69Hz​
​Resolution 10mHz​
​Accuracy 10mHz​
​​Control Power​ ​ ​
​Operating Range 100-260VAC: 50/60Hz 100-300VDC​
​Auxiliary DC Supply* 48VDC ​
​PoE In ​According to 802.3af
​Low Voltage Ride-Through Up to 25 Seconds​
 ​​​​​*Standalone Meter Panel includes 24VDC power supply.​
 ​​​
Standards​
Measurement Standards
EN50160, IEEE1159, IEEE519, IEC61000-4-15, IEC61000-4-7, IEC61000-4-30 Class A, IEC62053-22/23 Class 0.2
Electromagnetic Compatibility Standards
EN55011 Group 1 Class A, EN60439-1 (clause 7.9.1, 7.9.3, 7.9.4, 7.10,.3, 7.10.4), FCC Part 15 Subpart B Class A, IEC61000-3-3, EN61000-6-2, IEC60255
Environmental Standards IEC60068-2-1,2,6,11,27,30,75
Safety Standards UL508, EN61010-1: 2001 2nd Edition​
Product Images
​​PowerQuest Analytics allows for analysis of continuously recorded waveforms, energy consumption, time-of-Use, flicker, harmonics, transients, sags/swells, crest and K-factor. It also aggregates sequence of events form multiple meters synchronized to the millisecond with ITIC compliance curves. PowerQuest Analytics is available with the 5790 and 5900 Critical Power Management Systems.​

 





​​