Power Monitoring, 5210 | ASCO PowerQuest | Emerson

​PRODUCTS​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​

ASCO 5210
Digital Power Meter

The standard solution in monitoring an electrical circuit.

 

 Social Sharing

 
Product Downloads
Overview

Often times, existing sites are the locations with the most need for added monitoring, but are often the hardest to modify. The 5210 DPM has the flexibility to allow installation in numerous environments. The 5210 can be installed or retrofitted into new or existing Transfer Switches or switchgear..

Additionally the 5210 can be purchased pre-mounted in a wall mount enclosure for monitoring third party equipment, or as a loose meter for integration into other systems.

Regardless of where it is installed the 5210 will provide the needed data to allow knowledgable and insightful decision making on a daily basis.

Features
​​Metered Parameters
  • Voltages
  • Current
  • Power (kW, kVA & kVAR) & Power Factor
  • Frequency
  • Energy (kWh, kVAh & kVARh)
  • Total Harmonic Distortion (%)
  • Utilization
  • kW Demand (multiple periods and historical) Complies to NEC 220.87
  • Engine Run Time
  • Min/Max Historical Values

Devices Ratings

Current 0 to 5 ac nominal secondary CT. 4000 V ac isolation, minimum
Burden: Less than 0.25 VA per phase
Voltage​ 70 to 600 V ac nominal, phase to phase (Expandable via power transformers for medium voltage applications)
Frequency 45 Hz to 65 Hz fundamental. True RMS measurements up to and including the 31st harmonic.
Source Selection Input​ 26 V dc maximum, >10 V dc = active, <1 V dc = inactive
AC Power Requirements​ Minimum 70 V L-L Ac/103 mA / 7.2 VA with 50/60 Hertz (Parasitic from voltage sense lines)
DC Power Requirements ​Optional backup power supply 9-36 V dc 10 watts. DC power supply should be UL Listed.
​User Interface(s)​ ​Isolated RS485 - 2/4 Wire (for external Modbus RTU communication)
Optional ASCO Ethernet comm​unication module
Operating Temperature -4°F to 158°F (-20°C to 70°C)
Storage Temperature -22°F to 176°F (-30°C to 80°C)
​Measurement Category III
Pollution Degree PD 2
Humidity​ ​Relative humidity 5% to 85%, non-condensing
Accuracy1 ​0.25% Current, Voltage, Power, Frequency
1.00% Energy, Power Factor, Demand
Standards UL 61010-1
Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use
— Part 1: General Requirements
CSA-C22.2 No. 61010-1, 2nd Edition, 2004-07
Electrical Equipment for Measurement, Control and Laboratory Use
— Part 1: General Requirements
  
Ordering Information
Transfer Switch Accessory​ Acc 135 Family​
Tech Bundle Accessory​ Acc 150A for ATS2 Acc 150B for BPS2,3
Standalone Meter Kit (Meter & Manual Only) PN# 966071
In Type 1 Enclosure (5211 PMU)2,4 PN# 947905​
In Type 1 Enclosure with IO (5212 PMU)2,4 PN# 997684​

Notes:
  1. Further accuracy details available upon request in user manual.
  2. Includes ride through power module and ethernet communication module.
  3. Includes discrete IO module for bypass status.
  4. Enclosures include shorting blocks, fusing and auxiliary power supply.​
Product Images

ASCO 5210 Digital Power Meter mounted on a transfer switch including optional ASCO Ethernet communication module. (Remote webpage shown)

 





ASCO Services Mission-Critical Care

Our comprehensive service portfolio extends beyond routine maintenance to include solution upgrades and technology training that ensure you get the most from your emergency power systems.
1 800 800 ASCO (2726) customercare@asco.com