Firetrol FTA500 Jockey Pump Controller

Across the Line, Full Voltage Starting

Firetrol® FTA500 Jockey Pump Controllers are intended for use with fi re pump systems. They are used for pressure maintenance in fi re pump installations to prevent unnecessary cycling of the main fire pump.
 
Firetrol jockey pump controllers are listed by Underwriters’ Laboratories, Inc., in accordance with UL508, Standard for Industrial Controls, and CSA, Standard for Industrial Control Equipment. They are built to meet or exceed the requirements of the approving authorities as well as NEMA and the latest edition NFPA 70, National Electrical Code.

Features

The following are included as standard with each controller:

  • NEMA Type 2 (IEC IP11) drip-proof enclosure 
  • Horsepower rated disconnect switch, fuse block, and fuses 
  • Horsepower rated motor contactor and overload relay 
  • HAND-OFF-AUTO selector switch to allow manual operation of the pump 
  • Minimum run timer to prevent short-cycling 
  • 15-290 psi (1-20 bars) Pressure switch, diaphragmstyle, snap action type contact and 15-120 psi (1-8.3 bars) adjustable differential, suitable for freshwater applications. 
  • Control Circuit Transformer w/ 120VAC Secondary

The FTA500 Jockey Pump Controller utilizes across the line, full voltage starting. Full voltage is applied to the motor as soon as the controller is actuated, and the motor supplies its rated torque. When using full voltage starting, the power source must have suffi cient KVA capacity to handle motor locked rotor current and prevent the line voltage from dropping below acceptable levels.

When the controller is actuated, either by a drop in system pressure (in the “Auto” mode), or by placing the HAND-OFF-AUTO switch in the “Hand” position, the pump will start. In the “Auto” mode, the pump will continue to run until the pressure returns to a normal level and the minimum run timer has expired, whichever occurs last. In the “Hand” mode, the pump will continue to run until the HAND-OFFAUTO selector switch is moved from the “Hand” position.

The pressure switch is mounted inside the enclosure and is piped to a fi tting on the bottom of the enclosure.

Options/Modifications
Circuit Breaker Option
-A Standard Short Circuit Current Rating
200-240V - 65,000 Amps, RMS Sym.
380-480V - 25,000 Amps, RMS Sym.
550-600V - 14,000 Amps, RMS Sym.
NOTE: Consult Factory for high interrupting capacity circuit breakers.
Omit Minimum Run Timer
-B
Controller without minimum run timer
Floor Mounting Legs
-N2 FTA. Specify when ordering
Special Enclosures
-T NEMA Type 3R (IEC IP14)
-E NEMA Type 4 (painted steel) (IEC IP56)
-F NEMA Type 4X (#304 stainless steel) (IEC IP56)
-G NEMA Type 12 (IEC IP52)
*Note: Only the standard NEMA type 2 enclosures are supplied with a red fi nish - all other painted fi nishes are supplied Gray as standard. Consult factory for special paint color or fi nish.
Anti-condensation Space Heaters
-H 120 Volt space heater
-J 120 Volt space heater with thermostat
-K 120 Volt space heater with humidistat
-L 240 Volt space heater
-M 240 Volt space heater with thermostat
-N 240 Volt space heater with humidistat
*Note: Only the standard NEMA type 2 enclosures are supplied with a red fi nish - all other painted fi nishes are supplied Gray as standard. Consult factory for special paint color or fi nish.
Pressure Switches and Recorders
-B 20-675 psi (1.4-46.5 bars) Pressure Switch for freshwater service (Diaphragm Type, Snap Action Switch)
-C 5-250 psi (.35-17.2 bars) Pressure Switch for seawater/foam service (Diaphragm Type, Snap Action Switch)
-D 20-675 psi (1.4-46-5 bars) Pressure Switch for seawater/foam service (Diaphragm Type, Snap Action Switch)
-SL 0-300 psi (0-20.7 bars) pressure recorder for fresh water service
-SM 0-500 psi (0-34.5 bars) pressure recorder for
-SN 0-1,000 psi (0-69 bars) pressure recorder for fresh water service
Alarms
-AC Extra contacts (1 normally open & 1 normally closed) for remote indication, pump operating
-AM Contacts for remote indication, pump fail to start
-BY Contacts for remote indication, pump overload
-BW Contacts for remote indication, pump power failure
-BX Contacts for remote indication, phase reversal/ phase failure
Miscellaneous
-BJ Power ON pilot light
-BZ Elapsed time meter
-S Tropicalization
-R Pump operating pilot light
-GZ 50 Hertz operation
-SEI Seismic Certifi cation (in accordance with IBC)