Firetrol FTA1100 J Diesel Engine Fire Pump Controller Modifications 

Options and Modifications



The table below lists the available options and modifications to the diese engine fire pump controler. Use the Modifications navigation button to the right to select the option or modification you are considering. For other modications or selection assistance please contact our Applications Engineering.

Special Enclosures
-T NEMA Type 3R (IEC IP14)
-E NEMA Type 4 (IEC IP56) painted steel
-F NEMA Type 4X (IEC IP56) #304 stainless steel, natural finish**
-FXP NEMA Type 4X (IEC IP56) #304 stainless steel, painted finish
-FD NEMA Type 4X (IEC IP56) #316 stainless steel, natural finish**
-FDB NEMA Type 4X (IEC IP56) 12 guage, seam welded, #316 stainless steel, polished and brush finished
-FDP NEMA Type 4X (IEC IP56) #316 stainless steel, painted finish
-G NEMA Type 12 (IEC IP52)
** Natural finish ( Not painted, polished or brushed)

Mounting Legs
-N31 Standard 12" mounting legs
-N32 Base mounting legs 6"

Anti-condensation Space Heaters
-H 120 Volt space heater
-J 120 Volt space heater with thermostat
-K 120 Volt space heater with humidistat
-L 240 Volt space heater
-M 240 Volt space heater with thermostat
-N 240 Volt space heater with humidistat

Pressure Transducers
-B 0-600 psi (0-41.4 bar) pressure transducer for fresh water service
-C 0-300 psi (0-20.7 bar) pressure transducer for sea water/foam or copper corrosive applications
-D 0-600 psi (0-41.4 bar) pressure transducer for sea water/foam or copper corrosive applications

Remote Pump Room Trouble Alarms
-AC Additional contacts for remote indication, engine running - 2 sets provided as standard
-AT Contacts for remote indication, pump room trouble (common alarm)1
-AV Contacts for remote indication low pump room temp1
-AW Contacts for remote indication reservoir low1
-AY Contacts for remote indication low suction pressure1
-COM Visible low suction pressure alarm, manual reset only (includes reset push-button, initiating pressure switch not included)
-CPL Contacts for remote indication, system 115% over pressure (for use with PLD engines only)
-CTS Built-in low suction pressure alarm panel (includes selecable auto/manual reset, audible, visible and remote alarms and mounted and wired pressure switch)
-EH Contacts for remote indication relief valve discharge1
-EJ Visible flow meter on alarm1
-EK Contacts for remote indication flow meter on1
-JR Visible jockey pump running indication
-JT Audible and visible jockey pump trouble indication
-KH Contacts for remote indication, common output for any alarm
-LC Contacts for remote indication high fuel level1
-LD Visable fuel spill alarm1
-LE Contacts for remote indication fuel spill1
-LG Contacts for remote indication reservoir high1
-PE Contacts for remote indication remote low system pressure

Remote Engine Trouble Alarms
-AJ Contacts for remote indication, engine overspeed
-AK Contacts for remote indication, low oil pressure
-AL Contacts for remote indication, high water temp
-AM Contacts for remote indication, engine failed to start
-AN Contacts for remote indication, battery / charger failure
-EE Additional contacts for remote indication, engine trouble (common alarm) 1 set provided as standard

Remote Main Switch Mis-set Alarms
-AP Contacts for remote indication, main switch in manual
-AR Contacts for remote indication, main switch in off
-AS Contacts for remote indication, main switch in auto
-EF Additional contacts for remote indication, main switch mis-set, (common alarm) 1 set provided as standard

Miscellaneous
-AZ Low pump room temperature switch
-BA 220-240 Volt operation
-EL Series pumping, high zone controller
-EM Series pumping, mid zone controller(s)
-EN Series pumping, low zone controller
-S Tropicalization
-ZPA Customized, annual service display message (factory programmed)
-ZPM Serial Modbus RTU Communications Protocol
(Allows users to monitor all aspects
of the controller status via a RS485 communications
network (system integration
required). (Includes RS485 to twisted pair
breakout module, optical isolation module
(4000 ft. range) and customer connection
terminal blocks).
-ZPN 5150 Ethernet Connectivity Module (Allows
users to monitor limited controller
status via a single computer or over a
computer network)
- FTA1100-K1 Low fuel level switch, 16” max. insertion
length2
- FTA1100-K1-X High/Low fuel level switch - specify
levels/tank dimensions
- FTA1100-K2 Low fuel level switch, 25” max. insertion
length2
- FTA1100-K21 380-480 Volt operation (transformer)2
- Export packaging (Wooden crating to conform to
IPPC Standards)

1 Initiating switches by others
2 Shipped loose for installation by the customer