Our line of diesel engine fire pump controllers are available for use with 12 or 24 volt negative ground systems using lead acid or nickel-cadmium batteries. Firetrol® combined automatic and manual Mark II based diesel engine fire pump controllers monitor, display and record fire pump system information.

Product Information/Sales
Overview

Firetrol® combined automatic and manual Mark IIXG based diesel engine fire pump controllers are intended for starting and monitoring fire pump diesel engines. They are available for use with 12 or 24 volt negative ground systems using lead acid or Nickel-Cadmium batteries. The controller monitors, displays and records fire pump system information.

Firetrol Fire Pump Controllers are listed by Underwriters’ Laboratories, Inc., in accordance with UL218, Standard for Fire Pump Controllers, CSA, Standard for Industrial Control Equipment (cUL), and approved by Factory Mutual. They are built to meet or exceed the requirements of the approving authorities as well as NEMA and the latest editions of NFPA 20, Installation of Centrifugal Fire Pumps, and NFPA 70, National Electrical Code.

The Firetrol Mark II provides superior ease of operation and a greater range of options. Our common look and feel between the diesel and electric interfaces means reduced training time for operators of multiple installation applications. The ability to scroll through date stamped recorded data in steps of 1, 10, or 100 events allows users to quickly locate an event when doing diagnostics. And the Mark II's communications capabilities - supporting ModBus and other protocols - offers connectivity to a wide array of building management systems. The list goes on and on - text messaging instead of LED indicator lights, and the ability to add up to 8 customized alarms.

For immediate information contact your local Firetrol Representative or Firetrol directly at 919-460-5200.

Features
The following are included as standard with each controller:
  • AC Line & Battery circuit breakers
  • Manual-Off-Auto selector switch
  • Manual test push-button
  • Two manual crank push-buttons
  • Two 10 Amp battery chargers with 4 stage charging cycle, selectable AC voltage (110 / 220), selectable DC voltage (12 / 24), and selectable battery type (Lead Acid, Ni-Cad 9/18 Cell, Ni-Cad 10/20 Cell)
  • Door mounted display/interface panel featuring a 128 x 64 pixel backlit LCD graphical display, Membrane Type User Control Push-buttons and easy to read LED Indicators for:
  • AC POWER AVAILABLE
  • ALARM
  • MAIN SWITCH IN AUTO
  • MAIN SWITCH IN MANUAL
  • SYSTEM PRESSURE LOW
  • ENGINE RUNNING
  • ENGINE FAIL TO START
  • ENGINE TEMPERATURE HIGH
  • ENGINE OIL PRESSURE LOW
  • ENGINE OVERSPEED
  • ENGINE ALTERNATE ECM
  • ENGINE FUEL INJECTOR MALFUNCTION
  • FUEL LEVEL LOW
  • AUTOMATIC SHUTDOWN DISABLED
  • CHARGER MALFUNCTION
  • BATTERY #1 TROUBLE
  • BATTERY #2 TROUBLE
  • Minimum Run Timer / Off Delay Timer
  • Programmable Daylight Saving Time Option
  • Weekly Test Timer
  • Engine Run Time Meter
  • Digital Pressure Display
  • USB Host Controller and Port
  • Solid State Pressure Transducer
  • Data Log
  • Event Log (3000 Events)
  • Simultaneous Display of Battery Voltages, Charging Rates, AC Volts, Pressure and Alarm Messages
  • Disk Error message
  • Disk Near Full message
  • Pressure Error message
  • Fail To Start message
  • Low Suction Pressure Message
  • Crank Cycle Status Indication (Displays Cranking Battery, Number of Starting Attempts and Crank/Rest Time Remaining)
  • 300 psi (20.7 bar) wet parts (solid state pressure transducer, solenoid valve, plumbing) for fresh water applications
  • NEMA Type 2 enclosure (IEC IP22)
  • Each standard controller comes with user set options for:
  • AC Power Loss Start
  • Low Pressure Aud.
  • Main Sw. Mis-Set
  • Pump Run Alarm
  • User Defined Input
  • Low Pump Rm Temp
  • Relief Valve Open
  • High Reservoir
  • Interlock Alarm
  • Low Suction
  • Manual Test
  • Remote Start
  • Weekly Test Setup
  • Low Reservoir
  • High Fuel Level
  • Also included (as required) are Audible/Visible alarm notifications for:
  • Electronic Engine Control Module (ECM) Warning
  • Electronic Engine Control Module (ECM) Failure
  • Low Engine Temperature
  • High Raw Cooling Water Temperature
  • Low Raw Water Flow (Clogged Stainer)
  • Fuel Spill (Interstitial Space Liquid Intrusion)
  • Low Suction Pressure (At Variable Speed Suction Limiting Engine Controls)
Options/Modifications
SPECIAL ENCLOSURES
-E Enclosuer, NEMA Type 4 (IEC IP 66), Painted Steel
-F Enclosure, NEMA Type 4X (IP66), #304 Stainless Steel, Brushed Finish
-FD Enclosure, NEMA Type 4X (IP66), #316 Stainless Steel, Brushed Finish
-FDB Enclosure, NEMA Type 4X (IP66), #316 Stainless Steel, 12 Guage, Seam Welded, Brushed Finish
-FDP Enclosure, NEMA Type 4X, #316 Stainless Steel, Painted Finish
-FXP Enclosure, NEMA Type 4X (IP66), #304 Stainless Steel Painted Finish
-G Enclosure, NEMA Type 12 (IP54), Painted Steel
-T Enclosure, NEMA Type 3R (IP24), Painted Steel
MOUNTING LEGS
-N31 Mounting Legs, Standard 12 Inch, Painted Steel
-N31S Mounting Legs, Standard 12 Inch, Stainless Steel
ANTI-CONDENSATION SPACE HEATERS
-H Space Heater, 120V Externally Powered with Circuit Breaker
-J Space Heater, 120V Externally Powered with Circuit Breaker and Thermostat
-K Space Heater, 120V Externally Powered with Circuit Breaker and Humidistat
-L Space Heater, 240V Externally Powered with Circuit Breaker
-M Space Heater, 240V Externally Powered with Circuit Breaker and Thermostat
-N Space Heater, 240V Externally Powered with Citcuit Breaker and Humidistat
Pressure Transducers, Solenoid Valves, Plumbing
-B Wetted Parts Including Pressure Sensor, 600 PSI (42 Bar), Fresh Water
-C Wetted Parts Including Pressure Sensor, 300 PSI (21 Bar), Sea Water
-D Wetted Parts Including Pressure Sensor, 600 PSI (42 Bar), Sea Water
ALARMS
-AC Alarm Output Contacts, Extra, Engine Running (3 Sets)
-AJ Alarm Output Contacts, Engine Overspeed
-AK Alarm Output Contacts, Low Oil Pressure
-AL Alarm Output Contacts, High Water Temperature
-AM Alarm Output Contacts, Fail To Start
-AN Alarm Output Contacts, Battery / Charger Failure
-AP Alarm Output Contacts, Main Switch In Manual
-AR Alarm Output Contacts, Main Switch In Off
-AS Alarm Output Contacts, Main Switch In Auto
-AT Alarm Output Contacts, Pump Room Trouble1
-AV Alarm Output Contacts, Low Pump Room Temperature1
-AW Alarm Output Contacts, Reservoir Low1
-AY Alarm Output Contacts, Low Suction Pressure1
-COM Alarm, Audible/Visible/Output Contacts, Low Suction Pressure with Manual Reset Option. Pressure Switch Not Included1
-CPL Alarm Output Contacts, Overpressure(for use with PLD engines only)
-CTS Alarm, Audible/Visible/Output Contacts, Low Suction Pressure with Manual Reset Option and Pressure Switch
-ECMFR Alarm Output Contacts, Electronic Engine ECM Failure
-ECMWR Alarm Output Contacts, Electronic Engine ECM Warning
-EE Alarm Output Contacts, Extra, Engine Trouble (1 Set)
-EF Alarm Output Contacts, Extra, Main Switch Not In Auto (1 Set)
-EH Alarm Output Contacts, Relief Valve Discharge1
-EJ Alarm, Audible/Visible, Flow Meter On1
-HRTR Alarm Output Contacts, High Raw Water Temperature
-EK Alarm Output Contacts, Flow Meter On1 (Requires option -EJ)
-LETR Alarm Output Contacts, Low Engine Temperature
-LRFR Alarm Output Contacts, Low Raw Water Flow (Clogged Strainer)
-JR Visible Indicator, Jockey Pump Operating
-LSPR Alarm Output Contacts, Low Suction Pressure (at Variable Speed Suction Limiting Engine Controls)
-JT Alarm, Audible/Visible, Jockey Pump Trouble
-LC Alarm Output Contacts, High Fuel Leve1
-LE Alarm Output Contacts, Fuel Spill
-LG Alarm Output Contacts, Reservoir High1
-PE Alarm Output Contacts, Low System Pressure (Pump On Demand)
MISCELLANEOUS
-AZ Thermostat, Low Pump Room Temperature, Mounted and Wired
-BA AC Input, 220-240V
-EL Series Pumping Operation, High Zone Controller
-EM Series Pumping Operation, Mid Zone Controller
-EN Series Pumping Operation, Low Zone Controller
-IEC Marking, CE With External Wet Parts
-IECI Marking, CE With Internal Wet Parts
-OSP Marking, OSHPD Seismic Cerrtifi cation, State of California (Requires Option -SEI)
-S Tropicalization
-SEI Marking, Seismic Certifi ed (in accordance with IBC)
-USBX Data Port, External USB
-ZPA Scheduled Service Message
-ZPM

Data Port, Serial Modbus RTU Over 2-Wire or 4-Wire RS485

-ZPN

Data Port, Serial Modbus RTU Over Ethernet TCP/IP Serial Modbus RTU Over 2-Wire or 4-Wire RS485

   

FTA1100-K1 Low fuel level switch, 16” max insertion length2

FTA1100-K1-X High/Low fuel level switch - specify levels/tank dimensions

FTA1100-K2 Low fuel level switch, 25” max. insertion length2

FTAK21 380-480 volt operation (transformer)2

Export packaging (Wooden crating to conform to IPPC Standards)

1 - Initiating switches by others

2 - Shipped loose for installation by the customer

Product Information/Technical
Diagrams and Drawings
 
Technical Information
Firetrol Service Support
Keep mission-critical Firetrol Systems running at optimal levels.

+1 919 462 7105
24 x 7 x 365 respon​se
Learn More