The NetSure™ 802 introduces the highest efficiency, power factor corrected, 3-Phase input rectifier on the market.
Overview


The expanded NetSure™ 802 Series introduces separate, stand-alone power and distribution bays complementing the system’s compact combination bays and integrating easily with existing AC infrastructure. In addition, this system offers the highest efficiency, power factor corrected, 3-Phase input rectifier on the market. Overall system density now becomes a function of the number of load points that the end customer requires.

The base system offering provides a space savings of nearly 30% over conventional switch-mode power plants without sacrificing the overall cable management of the plant. The addition of integral AC Distribution (PDSC), battery disconnects, and comprehensive LMS1000 monitoring capabilities add value to the overall DC Power offering. The NetSure™ platform integrates these features into the entire DC system seamlessly with a depth of features never before seen in the industry.

Another primary concern addressed with this power system is the field safety of both the installation teams as well as the maintenance teams once the system is operational. With a fully enclosed bus system, the system provides a simple bolt-on solution for complete bay expansion that connects the –48 VDC and return busses with a single part per polarity. This element reduces the need for hundreds of pounds of copper and hours of assembly time during the installation or expansion process, along with allowing the system to be deployed into lower ceiling height buildings as well as raised floor data centers.

The NetSure™ 802 may be configured with traditional main battery termination bars. For these applications, we recommend EA343441 Series bars available in standard capacities from 4,000 amps to 16,000 amps.

Features
  • 16,000 amp plant capacity in a compact footprint
  • 2000 amp rectification plus distribution in single bay
  • Rectifier efficiency over 96%
  • Shunt monitoring for distribution positions over 70 amps
  • Internal inter-bay busswork eliminates overhead buss
  • Integrated LMS1000 remote monitoring system
  • NEBS Level 3 certified