The Edco SLAC surge protective device is specifically designed to protect electronic instruments used by the water/wastewater industries. It combines hybrid AC power protection and signal line protection in a NEMA-4X polycarbonate case. The AC power suppressor can supply up to 1,875 Watts and has a 15-Amp replaceable fuse to prevent overloading of the protective elements. A “Power On” LED provides visual indication that power is applied to instruments.

Signal line protection is accomplished by the Edco PC642 Series. All leads going to the Edco SLAC board are terminated by quick disconnect or barrier block connectors to facilitate easy removal for service or replacement.

  • Optional twist lock plug lightning & surge protection for AC power and low-voltage signal lines
  • Series hybrid AC suppressor/filter
  • Plug-in protection module
  • 15 Amp replaceable fuse
  • Test jacks for signal line monitoring
  • Power ON indicator
  • Optional stainless steel or fiberglass enclosure
  • 5 year warranty

AC Power

  • Technology: Three-Stage Series Hybrid
  • Input Voltage: 120 VAC 50/60 Hz
  • Output Current: 15 Amps Max.
  • Response Time: <5 Nanoseconds
  • Maximum Surge Current: (8x20µs): 10 kA
  • Occurrences at 500 Amps: >50


 Parameter Normal Mode (LN) Common Mode (L-G) (N-G)
IEEE 587 CAT A RING* 172V 280V
IEEE 587 CAT B RING* 205V 280V
IEEE 587 CAT B Impulse* 330V 360V


*Measured from zero volts, 90° Phase angle

Signal Line

  • Technology: Series Hybrid
  • Peak Surge Current: 10kA
  • Response Time: <1 Nanosecond
  • Voltage Clamp: 36V DC
  • Series Resistance: 5 (Typical)

Standard Enclosure

  • NEMA-4X
  • Glass-Filled Polycarbonate Base
  • Cover Molded in Clear Polycarbonate
  • Knockouts for 1/2" and 3/4" hubs
  • Bosses for 6 BZ x 3/8" Self-Tapping Screws
  • Maximum Protection - Total Insulation
  • Corrosion Resistant
  • Resists Temperature of 248°F
  • Flammability Rating: UL94-5V
  • Nominal Outside Dimensions (Inches): H=6.89 x W=6.89 x D=2.95

Optional Enclosure

  • NEMA-4X
  • Stainless Steel or Fiberglass
  • Continuous Hinge
  • Nominal Outside Dimensions (Inches): H=10 x W=8 x D=4
Technical Specification

Surge Suppression Products
Contact our support department about your Surge Protection product.

Telephone: +1 607 721 8840
Toll-Free: +1 800 288 6169

Contact Support