Separately Mounted


PRODUCTS

Separately Mounted

Firetrol Separately Mounted Power Transfer Switches are designed for use when pump room size constraints will not allow an integral controller/transfer switch confi guration, or where a transfer switch is now being required on an existing installation.
Product Information/Sales
Brochures and Data Sheets
 
Product Description
Overview
Firetrol® Separately Mounted Power Transfer Switches are designed for use when pump room size constraints will not allow an integral controller/transfer switch configuration, or where a transfer switch is now being required on an existing installation.
 

The power transfer switches are listed by Underwriters Laboratories, Inc. for transfer switch service and also meet the requirements of NFPA 20, Standard for the Installation of Stationary Pumps for Fire Protection and NFPA 70, National Electrical Code. The automatic/manual power transfer switches are listed by Underwriters Laboratories, Inc. under UL-1008, Automatic Transfer Switches, as well as UL-508, Industrial Control Equipment.

Separately mounted transfer switches are available in the following configurations:

FTA902 - For use with generator set emergency source - Required disconnecting means and overcurrent protection devices required for the normal side of the transfer switch are NOT supplied.

FTA903 - For use with generator set emergency source - Required disconnecting means and overcurrent protection devices required for the normal side of the transfer switch ARE provided.

FTA952 - For use with 2nd Utility emergency source - Required disconnecting means and overcurrent devices required for the normal side of the transfer switch are NOT supplied.

FTA953 - For use with 2nd Utility emergency source - Required disconnecting means and overcurrent devices required for the normal side of the transfer switch ARE provided.

Features
Firetrol Separately Mounted Automatic Transfer Switches feature the ASCO 7000 series transfer switch with Group 5 controller as standard. The microprocessor based controller includes a built-in keypad and four line LCD display mounted through the enclosure door. This allows all monitoring and control functions to be done with the door closed, providing convenience and safety.
The menu driven user interface allows setting changes to be made easily. These settings include:
  • Voltage and Frequency
  • Time Delays
  • Features
  • Engine Exerciser
  • Event Log
  • Service Features
Options/Modifications
CIRCUIT BREAKER
-N Intermediate withstand rating 200-600V - 150,000 Amps, RMS Sym.
-P High withstand rating Thermostat
200-600V - 200,000 Amps, RMS Sym. Humidistat
SPECIAL ENCLOSURES
-T NEMA Type 3R (IEC IP14), Painted Steel
-E NEMA Type 4 (IEC IP56), Painted Steel
-F NEMA Type 4X (IEC IP56), #304 Stainless Steel, Natural Finish (Not painted, polished or brushed)
-FXP NEMA Type 4X (IEC IP56), #304 Stainless Steel, Painted Finish
-FD NEMA Type 4X (IEC IP56), #316 Stainless Steel, Natural Finish (Not painted, polished or brushed)
-FDB NEMA Type 4X (IEC IP56), #316 Stainless Steel, 12 Gauge, Seam Welded, Polished and Brushed Finish
-FDP NEMA Type 4X (IEC IP56), #316 Stainless Steel, Painted Finish -G NEMA Type 12 (IEC IP52)
-G NEMA Type 12 (IEC IP52)
ANTI-CONDENSATION SPACE HEATERS
-H 120 Volt space heater
-J 120 Volt space heater with thermostat
-K 120 Volt space heater with humidistat
-L 240 Volt space heater
-M 240 Volt space heater with thermostat
-N 240 Volt space heater with humidistat
ALARMS
-EC Extra contacts for remote indication, transfer switch position
MISCELLANEOUS
-TN 5150 Ethernet Connectivity Module (ASCO Option 72E)
-S Tropicalization
Product Information/Technical

Firetrol Service Support

Keep mission-critical Firetrol Systems running at optimal levels.
+1 919 462 7105 24 x 7 x 365 respon​se

Learn More
​​