PRODUCTS


Liebert IntelliSlot Web Card Communications Interface Card

Emerson Network Power > EMEA > Products > AC Power and UPS > UPS Monitoring > Hardware > Liebert IntelliSlot Web Card Communications Interface Card
Liebert IntelliSlot Web Card family delivers SNMP, Telnet and web-management capability for enhanced communications and control of Liebert UPS, power management or precision cooling systems. Effective data center monitoring is provided by a wide range of operating parameters, alarms and notifications; transmitting data over the network.

Liebert IntelliSlot Web Card (formerly Liebert OpenComms Web Card and Liebert OpenComms NIC Card) delivers SNMP and Web management to a Liebert UPS, power management or precision cooling system connected to any 10- or 100-Mbit Ethernet network. The interface provides for remote web or in-the-field firmware upgrade. Alarms and parameters are transmitted over the network using SNMP, email, and SMS text. In addition, Liebert IntelliSlot Web Card w/Adapter supports Modbus.

  • Liebert IntelliSlot Web Card is compatible with the Liebert PowerSure PSI line-interactive UPS, Liebert GXT on-line UPS, Liebert GXT 6 & 10kVA on-line UPS, Liebert GXT 2U on-line UPS and Liebert Nfinity on-line UPS.
  • Liebert IntelliSlot Web Card LB is compatible with Liebert NX on-line UPS and Liebert Hinet on-line UPS.
  • Liebert IntelliSlot Web Card LBDS is compatible with Liebert DS and Liebert XDF precision cooling systems.
  • Liebert IntelliSlot Web/485 Card ADPT is compatible with Liebert power, UPS and precision cooling systems that are not equipped with an IntelliSlot port.
  • Liebert IntelliSlot 485 NXL card is compatible with Liebert NXL on-line UPS.
  • Liebert IntelliSlot Web Card L card is compatible with Liebert iCOM v.4 for all Liebert XDP iCOM, Liebert CRV and FW - PA1.04.033.STD or later for the Liebert DS, Liebert Challenger, and Liebert Deluxe.
  • Liebert IntelliSlot Web Card IPBML is compatible with Liebert iCOM v.4 for all Liebert XDP iCOM, Liebert CRV and FW - PA1.04.033.STD or later for the Liebert DS, Liebert Challenger, and Liebert Deluxe.
  • Liebert IntelliSlot Web Card S is compatible with Liebert PPC.
  • Liebert IntelliSlot Web Card IPBMS is compatible with Liebert PPC.
  • Web interface card with SNMP and Telnet capability
  • Provides alarm notifications via email and text messaging
  • Monitors UPS parameters via web browser
  • Operates compatibly with Liebert monitoring software
Features

Flexibility

  • Allows systems to be viewed from the network using a web browser.
  • Delivers SNMP, Telnet and web management.
  • Provides security using HTTPS message encryption.
  • Supports 10- and 100-MBit Ethernet for legacy and modern networks.

Higher Availability

  • Provides compatibility with Liebert MultiLink shutdown software, to prevent data loss and ensure data availability.
  • Supports Liebert SiteScan WEB enterprise monitoring software, to provide trending for proactive analysis and maintenance to ensure facility uptime.
  • Interfaces to Liebert Nform alarm notification software, to facilitate quick corrective action.

Lowest Total Cost Of Ownership

  • Allows use of existing network, saving the cost of dedicated wiring.
  • Requires no additional software installation for basic monitoring.
  • Provides notification in the absence of a comprehensive monitoring system.
  • Provides a single point of information/control.

Ideally Suited For

  • Small and large data centers
  • Computer rooms, network access spaces or server closets
  • Telecommunications facilities
  • Industrial process control centers
  • Other sensitive electronic applications
Benefits

Can I obtain a list of the supported SNMP Traps and parameters from the card?

Yes, on the Support Tab of the Web interface is the SNMP capabilities Information (i.e. Traps/Events, Parameters). In addition, this information is available via the serial connection and Telnet. Consult the User Manual for more details.

How many SNMP Trap targets can I configure in the Liebert IntelliSlot Web Card?

20

Is the Liebert IntelliSlot Web Card hot-swappable?

Yes, you will not be required to shutdown your UPS to install this card.

What is the default User Name and Password for the Liebert IntelliSlot Web Card?

User Name: Liebert
Password: Liebert

What Liebert products are supported by the IS-WEBCARD?

Liebert PowerSure PSI line-interactive UPS, Liebert GXT on-line UPS, Liebert GXT 6 & 10kVA on-line UPS, Liebert GXT 2U on-line UPS and Liebert Nfinity on-line UPS

What Liebert products are supported by the IS-WEBLB?

Liebert NX on-line UPS and Liebert Hinet on-line UPS.

Where can I obtain a user manual for my Liebert IntelliSlot Web Card?

http://www.emersonnetworkpower.com/en-EMEA/Products/Monitoring/ForLargeDataCenter/AdvancedMonitoring/Pages/LiebertIntelliSlotWebCardCommunicationsInterfaceCard.aspx

Where can I view and test drive the web interface for the product I am purchasing?

http://demos.liebert.com/

Product FAQs

Liebert IntelliSlot, Web Card Interface MIBs
For all devices and operating systems

Firmware

 Firmware OCWEBCARD HID3 2.400.3 (R 06/10)
OC-WEB Card found in small UPS units
 Firmware IS-WEBCARD HID6 3.100.3 (R 06/10)
IS-WEB Card found in small UPS units
IS-WEBCARD HID9 5.300.0_069348 (08/12)
Web, SNMP - GXT3, Nfinity
 RPC_HID16_4.940.0_069682 (08/12)
Web, SNMP - MPX and MPH rack PDUs
 Firmware IS-WEBLBDS HID7 3.210
IS-WEB Card found in Liebert DS air units
 Firmware OCNIC_REV2_BLD94
OpenComms NIC and NIC-485, running version 2.x
 Firmware OCWEB-ADPT_HID5_3_121_1 (01/10)  
OCWEB Adapter found in large Air, UPS and Power units, running version 3.x
 Firmware IS-WEBLB HID7 3.310.3  (R 06/10)
IS-WEBLB Card found in NX UPS units
 Firmware IS-WEBLB_HID10_5.010.1 (06/10)
IS-WEBLB Card found in NX UPS units
 IS-IPBML _HID10_5.1E0.0_069921 (8/12)
Modbus IP, BACnet IP – v4- Cooling and APM
 IS-485L_HID12_5.290.0_069921 (8/12)   
Modbus 485 – v4 - Cooling and APM
IS-WEBL_HID10_5.280.0_069921 (08/12)
Web, SNMP -v4- Cooling and APM
 Firmware OC485-LBDS-FW_REV1 (R 3/08)
 Firmware OCWEB-LBDS HID5 3.210.0 (R04/09)

IS-WEBX_HID14_6.1J0.1_070423 (08/12)
Web, SNMP -v4- NXL

IS- WEBADPT_HID10_5.2A0.1_069833 (8/12)
Web, SNMP, Modbus 485 – IGM - UPS, Cooling, Power Equipment

IS-485X_HID13_6.1D0.1_070423 (8/12)
Modbus 485 – v4 - NXL

IS-IPBMX_HID14_6.1C0.3_070423 (8/12))
Modbus IP – v4 - NXL

MIBS

 MIB for Unix Based Systems 192435P1 REV 3
 MIB for Windows Based Systems 192436P1 REV 3

Software Download

Monitoring Products
Contact our Liebert support department about your monitoring software and hardware.

Contact Support