The Edco CX06-M & Edco CX06-MI and CX06-MI-SBL Surge Protective Devices (SPDs) implement three-stage hybrid technology. Sneak and fault currents are mitigated with solid-state resettable fuses—PTCs. The Edco CX06-M and Edco CX06-MI SPDs and CX06-MI-SBL are designed in accordance with NFPA 780 (2004 edition) requirements, with up to 20kA of surge current capability. The Edco CX06-MI and Edco CX06-MI-SBL model has an isolated ground and is recommended for use at the camera end.

For a high-energy camera protection package the Edco CX06-MI may be purchased in combination with the Edco FAS-1043 HC low voltage power protector by ordering the Edco FAS-CXMI.

  • Sneak/fault current protection
  • Shielded case
  • CX06-MI and CX06-MI-SBL has an isolated ground
  • 5 year warranty
  • Low insertion loss
  • Operating Voltage: 5 VDC
  • Clamping Voltage: 6 VDC
  • Operating Current: 0.15 A
  • Peak Surge Current: 20 kA (8 x 20µs)
  • Frequency Range: 0 - 20 MHz
  • Insertion Loss: < 0.1 dB at 20 MHz
  • Response Time: >.5ns
  • SPD Technology: GDT, SAD, w/Series PTC
  • Connection Type: BNC, 50/75 Ohm
  • Operating Temperature: -40°C to +85°C
  • Dimensions (Inches):
    • M = 1.5H x 1W x 3.25
    • MI = 1.5H x 1W x 4L
    • SBL = 1.7H x 1.4W x 2.8L
  • Weight: M = 2.3 oz   MI = 3 oz  SBL  SBL = 3 oz
  • Certifications: UL 497B Listed