Tecoras Street Cabinet HEC with Double Door

Tecoras Street Cabinet HEC with Double Door

Emerson Network Power > CHINA > Products > By Type > Outside Plant > Wireless Solutions > Outdoor Enclosures > Tecoras Street Cabinet HEC with Double Door
  • Single-wall cabinet with air-to-air heat exchange integrated in the rear panel with 1 48 VDC fan for inner and 1 for outer circulation, thermostat controlled
  • All bolting and connection elements situated inside
  • Hinged solar protection roof
  • 1 Front door, double-winged, closed, right door wing with lock and release lever for extrusion half-cylinder with saw protection, triple interlocking
  • Door lock-in, lock-out with opening angles of 90° and 135°
  • Sound pressure level less than 55 dB(A) at a distance of 1 m in accordance with ISO 7779
  • Features

    Variants

    • Type 1
      ■ With external cover panels of aluminium AlMg3, 2 mm ( order number 01.917.XXX.1
    • Type 2
      ■ With external cover panels of hot-galvanized sheet steel DX 51 D + Z 140, 1.5 mm ( order number 01.918.XXX.1 )

    For the installation of

    • 2 x components in accordance with IEC 297-3 (19") or IEC 917 (metric)
    • Non-standard equipment with max. installation width of 1100 mm for DIN rail and assembly panel mounting

    Load rating

    • 4000N static

    Standards

    • Built-in units in accordance with IEC 297-3 (19") and IEC 917 (metric)
    • Earthing in accordance with VDE 0100
    • IP protection in accordance with EN 60529
    • Sound pressure in accordance with ISO 7779

    Degree of protection

    • IP 54

    Tests

    • Environmental test in accordance with IEC 68-2-1, IEC 68-2-2, IEC 68-2-5, IEC 68-2-56
    • Vibration tested in accordance with IEC 68-2-6
    • Earthquakeproof to zone 4 in accordance with Telcordia GR-63-CORE

    Material / Finish

    • Type 1
      ■ Basic rack: extruded aluminium AlMgSi0,5
      ■ Corner piece: die-cast aluminium
      ■ Solar protection roof: aluminium AlMg3, 2 mm
      ■ External cover panels of aluminium AlMg3, 2 mm
      ■ Ribbed rear panel (heat transfer system): aluminium AlMg3, 2 mm
      ■ Chrome-plated, powder-coated front quality in accordance with GSB International, coarse textured
    • Type 2
      ■ Basic rack: extruded aluminium AlMgSi0,5
      ■ Corner piece : die-cast aluminium
      ■ Solar protection roof: aluminium AlMg3, 2 mm
      ■ External cover panels of hot-galvanized (zinc-coated) sheet steel 1.5 mm
      ■ Ribbed rear panel (heat transfer system): aluminium AlMg3, 2 mm
      ■ Powder-coated front quality in accordance with GSB International, coarse textured

    Colour

    • RAL 7035 light grey

    Supply schedule

    • 1 Basic rack with cover and base
    • 1 Double-wall ribbed rear panel with air baffle
    • 1 Fan module with 2 fans, thermostat controlled
    • 2 Side panels
    • 1 Solar protection roof
    • 1 Front door, double-winged, closed
    • 1 Earthing set

    How supplied

    • assembled

    Principle of the integrated heat exchanger

    • Integration of heat transfer system in the rear panel
    • Installation of fans and electronis control in the roof
    • Optimal layout of air intake and air aoutflow causes lowest wind intake and elimination of airflow disruption
    Technical Specifications
    tecoras street cabinet with closed front door, double-winged, with air-to-air heat exchangerorder number
     WIDTH    INSTALLATION
          WIDTH
    DEPTH    USEABLE
      DEPTH
    TYPEHEIGHT  INSTALLATION
          HEIGHT h
     
    MAX. SEC. COOLING CAPACITY                   
    B [mm]      b [mm] T [mm]  t [mm] H [mm]  [U][mm]            [W/K]*
    1210  1105                  375   310178014630 2501.917.240.1
    1000198503001.917.241.1
    11802310303301.917.242.1
              
         
         
    475410   1780146302501.917.245.1
    1000198503001.917.246.1
    11802310303301.917.247.1