Tecoras Heat Exchanger Cabinet

Tecoras Heat Exchanger Cabinet

  • Double-wall outdoor enclosure
  • With EMC sealing
  • With air-to-air heat exchanger with 1 48 VDC fan for the outer and inner air circulation, thermostat controlled
  • Active vented and ribbed side and rear panels
  • All bolting and connection elements situated inside
  • Hinged solar protection roof
  • Doorstop changeable
  • Door with lock and release lever for extrusion half-cylinder with saw protection, triple interlocking system, closed
  • Door lock-in, lock-out, with opening angles of 90° and 135°
  • Sound pressure level less than 55 dB(A) at a distance of 1 m in accordance with ISO 7779
Features

 For the installation of

  • Components in accordance with IEC 297-3 (19") or IEC 917 (metric)
  • Non-standard equipment with max. installation width of 535 mm

Load rating

  • 4000N static

Standards

  • Built-in units in accordance with IEC 297-3 (19") and IEC 917 (metric)
  • Earthing in accordance with VDE 0100
  • IP protection in accordance with EN 60529Sound pressure in accordance with ISO 7779

Degree of protection

  • IP 55

Tests

  • Environmental test in accordance with IEC 68-2-1, IEC 68-2-2, IEC 68-2-5, IEC 68-2-56
  • Vibration tested in accordance with IEC 68-2-6
  • Earthquakeproof to zone 4 in accordance with Telcordia GR-63-CORE
  • Shielding attenuation in accordance with IEC 61 587-3 at least 25 dB

Material / Finish

  • Basic rack: extruded aluminium AlMgSi0,5
  • Corner piece: die-cast aluminium
  • Internal cover panel: aluminium AlMg 3, 1.5 mm thick, chrome-plated
  • External cover panel: aluminium AlMg 3, 2 mm thick, chrome-plated, powder-coated front quality in accordance with GSB International, coarse textured
  • Plinth frame: zinc passivated sheet steel
  • Plinth cover panel: hot-galvanized (zinc-coated) sheet steel DX51 D + Z 140, 1.5 mm

Colour

  • RAL 7035 light grey

Supply schedule

  • 1 Basic rack with base and 2 corner extrusions
  • 1 Double-wall, ribbed rear cover panel with internal air baffle
  • 2 Double-wall, ribbed side cover panels with internal air baffle
  • 1 Fan module with 2 fans 48 V DC, thermostat controlled for air circulation inside/outside
  • 1 Solar protection roof
  • 1 Front door, opens to the right, closed
  • 1 Plinth frame 210 mm high, with 2 side cover panels, with
  • 1 front and 1 rear removeable panel
  • 1 Earthing set
  • 1 Cable entrance panel, closed

How supplied

  • assembled

Princible of the integrated heat exchanger

  • Integration of the heat transfer systemin the outer panels
  • Installation of fans and electronic control in the roof
  • Optimal layout of air intake and air outflow causes lowest wind intake and elimination of airflow disruption
Technical Specifications
TEcoras heat exchanger cabinetorder number
WIDTH    INSTALLATION
     WIDTH
DEPTH      USEABLE
  DEPTH
HEIGHTINSTALLATION
     HEIGHT h  
MAX. SEC.
COOLING CAPACITY                    
 
B [mm]      b [mm] T [mm]  t [mm]H [mm][U] [mm]             [W/K]* 
700535405 330100019 850 2801.900.003.1
11802210304001.900.005.1
14002812504301.900.007.1
15803214304801.900.009.1
7056301000198504801.900.023.1
11802210305501.900.025.1
14002812505801.900.027.1
15803214306301.900.029.1
1335   1070     405300100019850 5501.900.401.1
11802210306801.900.402.1
14002812507001.900.403.1
15803214307801.900.404.1
 7056001000198507301.900.411.1
11802210308501.900.412.1
14002812508801.900.413.1
15803214309801.900.414.1
Product Downloads
Brochures and Data Sheets