Emerson | Firetrol FTA550E XG Jockey Pump Controller


PRODUCTS
Firetrol FTA550E XG Jockey Pump Controller

Across the Line, Full Voltage Starting

Emerson Network Power > CALA > Products > By Type > Fire Pump Controllers > Jockey XG Pump Controllers > Firetrol FTA550E XG Jockey Pump Controller
Firetrol® FTA550E XG Jockey Pump Controllers are intended for use with fire pump systems. They are used for pressure maintenance in fire pump installations to prevent unnecessary cycling of the main fire pump.

NOTE: FTA550E XG Jockey Pump Controllers are available as standard in the voltage/horsepower combinations shown here and with the Options/Modifications shown on the tab below. For other combinations and options, please contact your Firetrol representative or the factory.

VOLTAGE 3-PHASE
(50/60 Hertz)
MAX HP Short Circuit
(50/60 Hertz) Current Rating
-H 200 - 208V 25 65kA
-A 220 - 240V 30 65kA
-F 380 - 415V 40 65kA
-B 440 - 480V 50 65kA
-C 550 - 600V 50 25kA

VOLTAGE 3-PHASE*
(50/60 Hertz)
MAX HP Short Circuit
(50/60 Hertz) Current Rating
-D 110-120V 5 200kA
-T 200-208V 15 200kA
-E 220-240V 15 200kA

* Single phase units supplied standard with fusible disconnect switch and fuses

Firetrol jockey pump controllers are listed by Underwriters’ Laboratories, Inc., in accordance with UL508, Standard for Industrial Controls, and CSA, Standard for Industrial Control Equipment. They are built to meet or exceed the requirements of the approving authorities as well as NEMA and the latest edition NFPA 70, National Electrical Code.

The following are included as standard with each controller:

  • NEMA Type 2 (IEC IP11) Painted Steel Enclosure
  • Circuit Breaker
  • Horsepower rated motor starter
  • Suitable for use as service equipment
  • HAND-OFF-AUTO selector switch
  • Minimum run timer
  • On-Delay timer
  • Pump Restart Timer
  • Control circuit transformer with 24VAC secondary
  • 0-300 psi (0-20.7 bar) stainless steel solid state pressure transducer
  • Overpressure indication
  • Low Pressure indication
  • Failed to start indication
  • Main switch not in "Auto" alarm
  • Pressure recording
  • Event log (3000 events stored in controller memory)
  • Data log (including cycle counter)
  • Door mounted display/user interface featuring a 128 x 64 pixel backlit LCD Graphical Display, Membrane Type User Controller Push-buttons and LED indication for:
    • Power ON
    • Pump Running
    • Alarm
  • 2 lines of user selectable display information
Features
SPECIAL ENCLOSURES
-T NEMA Type 3R (IEC IP14)
-E NEMA Type 4 (IEC IP56)
-F NEMA Type 4X (IEC IP56)
-FXP NEMA Type 4X (IEC IP56), #304 Stainless Steel, Painted Finish
-FD NEMA Type 4X (IEC IP56), #316 Stainless Steel, Unfinished**
-FDB NEMA Type 4X (IEC IP56), 12 Gauge, Seam Welded, #316 Stainless Steel, Polished and Brushed Finish
-FDP NEMA Type 4X (IEC IP56), #316 Stainless Steel Painted Finish
-G NEMA Type 12 (IEC IP52)
** Unfinished (Not painted, polished or brushed)
HIGHER SHORT CIRCUIT CURRENT RATING
AF Model (See selection data sheet)
Fusible Disconnect Switch with Fuses (200kA)
ANTI-CONDENSATION SPACE HEATERS1
-H 120 Volt Space Heater
-J 120 Volt Space Heater With Thermostat
-K 120 Volt Space Heater With Humidistat
-L 240 Volt Space Heater
-M 240 Volt Space Heater With Thermostat
-N 240 Volt Space Heater With Humidistat
1 Power source supplied by others
PRESSURE TRANSDUCERS
-C 0-300 psi (0-21.1 bar) Pressure Transducer for corrosive service
-D 0-600 psi (0-42.25 bar) Pressure Transducer for Corrosive Service
MISCELLANEOUS
-AC Contacts for Remote Indication, Pump Run
-AG Built-in reservoir low alarm (visible)
-AM Contacts for Remote Indication, Failed to Start
-AST Auto Start Contacts (for connection to user supplied N.O. remote starting device)
-AW Contacts for Remote Indication, Reservoir Low
-BW Contacts for Remote Indication, Phase Failure/Reversal
-BY Contacts for Remote Indication, Pump Overload
-CPL Contacts for remote indication, system overpressure
-EF Contacts for Remote Indication, Switch Not in Auto
-HV Audible Alarm
-KH Contacts for Remote Indication, Common Output for Any Alarm
-NZ Interlock Input Contacts to Prevent Jockey Pump from Starting During Main Controller Operation
-PE Contacts for remote indication, low system pressure
-S Tropicalization
-SEI Seismic Certifi cation (in accordance with IBC)
-ZPA Customized, annual service display message (when factory programmed or rogrammed by Firetrol representative during start-up)
-ZPJ Communications, Serial Modbus over RS485, 2 or 4 wire
*Export Packaging available for additional cost

NOTE: For requirements not listed here, please contact your Firetrol representative or the factory.

Options/Modifications
Brochures and Data Sheets
Product Information/Sales
Diagrams and Drawings
Technical Information
Product Information/Technical

Firetrol Service Support
Keep mission-critical Firetrol Systems running at optimal levels.

+1 919 462 7105
24 x 7 x 365 respon​se
Learn More