MPH2 - Managed Rack PDU


PRODUCTS
​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​
​MPH2™, Managed Rack PDU

Advanced Monitoring
and Control Support

​​
Emerson Network Power > CALA > Products > By Type > AC Power / UPS > Rack PDU > MPH2 - Managed Rack PDU

MPH2 is the most intelligent, high-availability line of managed rack PDUs. It offers remote monitoring and control capabilities as well as environmental input options, with multiple power input selections and output configurations, allowing data center power control to the receptacle level, as well as monitoring of the strip and environmental input options, such as rack temperature and humidity. MPH2 offers the industry's leading operating temperatures, ensuring availability even in the harsh environment at the back of the rack.

It is available in the following versions:

  • Outlet Level Metered and Switched
  • Outlet Level Metered
  • Rack PDU Metered and Outlet Switched
  • Rack PDU Metered
​​
  • Onboard display
  • Managed rack-installed power strip
  • Monitors at branch level
  • SN Sensors
  • Controls at equipment level
  • Offers single-phase and three-phase models
​​Features
​​

Designed for High Availability

  • Designed specifically to accommodate higher power densities and be resistant to higher temperatures.
  • Easily upgradable to minimize downtime and carry manufacturer-provided support to ensure your own SLAs.
  • Easily integrate with existing network and security architectures, as well as higher level management software – allowing you to operate at peak velocity.

Designed to Enhance Energy Efficiency and Capacity Management

  • Energy and power metering provides users the information to maximize the data center power and cooling infrastructure.
  • Integration into Smart Solutions.
  • Modular hot swappable controller card – separates power distribution and communications, enabling continuous distribution when a communications module fails or is replaced.

Designed to Improve Business Resiliency and Agility:

  • Allows you to predict failing conditions before they occur and proactively manage connected equipment for maximum uptime.
  • Power and environmental trend reports through integration with Avocent® Rack Power Manager, Liebert Nform™ and the Trellis™ platform – improved monitoring, control, and reporting of trends.
  • Seamless integration within federal government and enterprise networks.

Designed to Reduce Deployment Time and Expenses:

  • Lowest power consumption of all switched rack PDU designs ensures lower operating costs for datacenter.
  • Provides full featured monitoring and control in a cost effective package.
  • A Rack PDU Array™ shares a single IP address for up to four rack PDUs, making deployment faster and easier.
  • Ability to be preinstalled in Emerson Network Power rack solutions – save time and money on deployment.
Benefits
​​​

Local Liebert Representative
Contact your local Liebert NA Representative at your location.

Network and Rack UPS Products
Contact our support department about your Liebert network and rack UPS system.

Sales, Service, and Support
1-800-222-5877
Outside the US: +800-1155-4499

Support
MPH2™ - Specifications

Mounting

Preinstalled Toolless brackets, Universal Mounting bracket Ability to ship rack PDU preinstalled in Emerson Racks

Input Power Options
North America

100 - 120V 1-ph 20A/30A
200 - 240V 1-ph 20/30A
200 - 240V 3-ph 20/30/50/60A
208/120V 3-ph 20/30A
415V/240V 3-ph 20A/30A

Input Power Options International

230V 1-ph 16A/32A
230/400V 3-ph 16A/32A/63A

Input Wiring Options

10 ft. pluggable power cord or Hardwired

Max. Capacity North America

17.2 kW

Max. Capacity International

22.2 kW

Outlet Options

NEMA 5-20; IEC 320C13
IEC 320 C19
Locking capability on all outlets

Maximum Outlets

Strip Metered: 42
Outlet Metered and / or
Switched: 24

Maximum Operating Temp. Range

0°C to 60°C
(32°F to 140°F)

Storage Temperature Range

-25°C to 85°C
(-13°F to 185°F)

Relative Humidity

5% to 95%

Overcurrent Protection

Software Electronic Overcurrent Protection
100% Rated 20A Branch Overcurrent Protection -
Hydraulic Magnetic
Circuit Breakers

Idle Power Consumption

3W - 5W

0U Units Width
x Depth

56 mm x 50 mm
(2.2 in x 1.96 in)

0U units Length

916 mm / 1004 mm /
1737 mm/ 1827 mm
(36 in) / (39.5 in) /
(68.4 in) / (72 in)

Standard Warranty

2 years; Extended Warranties Available

Agency Approvals

UL, CSA, CE, RoHS, REACH,
FCC Class A, CB, WEEE, ISTA

Metering Levels

Aggregate, Branch, Phase, Outlet

Parameters Measured

Volts, Current, kW, KVA, kWh, Power Factor, Crest Factor, Frequency

Metering Accuracy

+/-1%

Switching Capability

On, Off, Recycle, Lock, Unlock,
Outlet Grouping Capability

Modularity

RPC2 communications module

Local Management

Onboard Display,
Optional Local Display

Remote Management

Onboard Web Interface; CLI; SNMP; SSH; Telnet
Integration with Avocent® ACS, Avocent Universal Management Gateway & Avocent MergePoint™ Unity Integration with DSView®, Rack Power Manager, Nform™ and the Trellis™ platform

SNMP version support

v1, v2 and v3

Authentication

Local
Remote: Active Directory, LDAP, TACACS,
Radius, Kerberos

Encryption

MD5, AES, DES

Specs
​​

MPH2 - Managed Rack PDU
North American Models

SKU

Specifications

Dimensions

Form Factor

Input

Output

Functionality

Voltage

Current

Plug

Voltage

Outlets

MPHC1403

0U

100 - 120V 1-ph

20A

L5-20

100 - 120V

18 5-20R

Rack PDU Metered + Outlet Switched

68.4" (L) x 2.2" (W) x 2.0" (D)

MPHC1112

0U

200 - 240V 1-ph

30A

L6-30

200 - 240V

18 C13 + 6 C19

Rack PDU Metered + Outlet Switched

68.4" (L) x 2.2" (W) x 2.0" (D)

MPHC1212

0U

200 - 240V 1-ph

30A

L6-30

200 - 240V

24 C13

Rack PDU Metered + Outlet Switched

68.4" (L) x 2.2" (W) x 2.0" (D)

MPHC1123

0U

208/120V
3-ph

30A

L21-30

208V

18 C13 + 6 C19

Rack PDU Metered + Outlet Switched

68.4" (L) x 2.2" (W) x 2.0" (D)

MPHC1131

0U

415/240V
3-ph

30A

L22-30

240V

18 C13 + 6 C19

Rack PDU Metered + Outlet Switched

68.4" (L) x 2.2" (W) x 2.0" (D)

MPHC1331

0U

415/240V
3-ph

30A

L22-30

240V

6 C13 + 12 C19

Rack PDU Metered + Outlet Switched

68.4" (L) x 2.2" (W) x 2.0" (D)

MPHR1403

0U

100 - 120V 1-ph

20A

L5-20

100 - 120V

18 5-20R

Outlet Metered + Outlet Switched

68.4" (L) x 2.2" (W) x 2.0" (D)

MPHR1404

0U

100 - 120V 1-ph

30A

L5-30

100 - 120V

18 5-20R

Outlet Metered + Outlet Switched

68.4" (L) x 2.2" (W) x 2.0" (D)

MPHR1112

0U

200 - 240V 1-ph

30A

L6-30

200 - 240V

18 C13 + 6 C19

Outlet Metered + Outlet Switched

68.4" (L) x 2.2" (W) x 2.0" (D)

MPHR1212

0U

200 - 240V 1-ph

30A

L6-30

200 - 240V

24 C13

Outlet Metered + Outlet Switched

68.4" (L) x 2.2" (W) x 2.0" (D)

MPHR1122

0U

200 - 240V 3-ph

30A

L15-30

200 - 240V

18 C13 + 6 C19

Outlet Metered + Outlet Switched

68.4" (L) x 2.2" (W) x 2.0" (D)

MPHR1123

0U

208/120V
3-ph

30A

L21-30

208V

18 C13 + 6 C19

Outlet Metered + Outlet Switched

68.4" (L) x 2.2" (W) x 2.0" (D)

MPHR1523

0U

208/120V
3-ph

30A

L21-30

208/120V

12 C13 + 4 C19 + 6 5-20R

Outlet Metered + Outlet Switched

68.4" (L) x 2.2" (W) x 2.0" (D)

MPHR1131

0U

415/240V
3-ph

30A

L22-30

240V

18 C13 + 6 C19

Outlet Metered + Outlet Switched

68.4" (L) x 2.2" (W) x 2.0" (D)

MPHR1331

0U

415/240V
3-ph

30A

L22-30

240V

6 C13 + 12 C19

Outlet Metered + Outlet Switched

68.4" (L) x 2.2" (W) x 2.0" (D)

MPHM3341

0U

100 - 240V 1-ph

20A

IEC C20 connector

100 - 240V

8 C13

Outlet Metered

36.1" (L) x 2.2" (W) x 2.0" (D)

MPHM3141

0U

100 - 240V 1-ph

20A

IEC C20 connector

100 - 240V

16 C13

Outlet Metered

36.1" (L) x 2.2" (W) x 2.0" (D)

Configurations

​​
So What Should You Do Next?
Go to our PDU quick form to request more information.
Click Here
MPH2 Rack PDU Switched Model Energy Savings
Enter your data center variables, then click the Compute button to see how much money you can save by using the highly efficient switched models of the MPH2 rack PDU.
Cost of Energy ($/kWh)
Datacenter PUE*
No. of PDU's in a Rack
No. of Racks in datacenter
Typical 24 Outlet Switched Rack PDU MPH2
Rack PDU power consumption (Watts)
Rack PDU annual energy consumption (kWh) - 24x7x365
Overall contribution to datacenter energy consumption (kWh)*
Cost of energy consumption ($)
Annual savings per PDU with MPHC/MPHR ($)
Annual Savings per Rack with MPH2
Annual Savings within the datacenter with MPH2

* Average US datacenter PUE ~1.8