Rack PDUs | PM 1000/2000/3000 | Avocent


PRODUCTS​​​​​​
Avocent® PM 1000/2000/3000
Rack PDUs
Advanced power measurement, control and management for your remote IT equipment
Emerson Network Power > CALA > Products > By Type > AC Power / UPS > Rack PDU > Avocent® Managed Rack PDU - PM 1000-2000-3000

The Avocent® Power Management Distribution Units (PM PDUs) include single-phase and three-phase models that support strip-level metering, outlet-level metering or outlet-level metering and switching. This advanced family of rack PDUs includes horizontal and vertical models for a variety of rack configurations in branch and remote offices. With the ability to support up to 22 kW and models that include support for C19 outlets, the Avocent® PM PDUs are well positioned to support the high rack density found in organizations today.

The PM PDUs include a LED display and a built-in browser interface for local and remote access to real-time data. The metering features, along with the capability to set custom thresholds, allow companies to optimize their electrical infrastructure, without the risk of downtime due to overloaded circuits.

The PM 1000 PDUs enable companies of all sizes to accurately measure the current, voltage and power for the entire strip and the circuits within. The PM 2000 and PM 3000 PDUs take this a step further to support outlet-level metering and switching capability (PM 3000 PDUs only) to provide data center professionals the tools they need to monitor, measure, reduce and manage the growing power consumption costs of IT equipment.

All of these PDUs include advanced features that consist of a built-in network port for access to the browser interface, daisy chain ports for easy installation and expansion and support for external, environmental sensors.

For a total solution, the PM 1000/2000/3000 devices can be used with other Avocent® appliances for integrated IP access to the attached equipment, along with power measurement and/or control for improved remote management.

When used with the Avocent® DSView™ management software, users gain secure access and control across multiple locations. The optional Avocent® DSView™ Power Manager plug-in allows real-time and historical reporting of capacity, consumption and cost across single PDUs or groups of PDUs.

Need more information? Click here and talk to us.

Features and Benefits

  • Outlet-Level, Phase-Level and Strip-Level Current/Voltage/Power Metering with Threshold/Alert Capabilities - Provides preemptive notification of any impending overload issues before they occur and simplifies the task of installing new equipment (Note- measurement resolution +/- 5%)
  • Capability to Remotely Switch Outlets Through On-Board Web Interface, Avocent DSView management software - Allows power to hung up IT equipment to be recycled, turned on or turned off remotely for faster resolution time (not available on PM 1000 or PM 2000 PDUs)
  • On-Board Web Interface - Can be installed for direct access right out of the box or it can be configured as part of a larger integrated solution using the Avocent DSView management software
  • IP and Serial Interface Options - Options to install by connecting directly to the network or save IP connections by using the serial interface to connect directly to Avocent appliances already connected to the network
  • Daisy Chaining - Saves the number of IP addresses or console/KVM ports that are required to manage all power distribution needs
  • Integration with Avocent DSView management software - Single interface for management of IT equipment and PDUs simplifies mapping of outlets to servers and other equipment in order to reduce and minimize power cycling the wrong equipment
  • Integration with Avocent DSView Software Power Manager Plug-In - Track historical trends to measure and monitor IT power consumption, capacity and cost in order to understand what issues exist and to make more informed decisions in the future
  • Electronic Overcurrent Protection - An added layer of protection that is activated in the event of minor overloads; during such events, outlets are turned off first instead of the primary overcurrent protection (OCP) tripping
  • Sequential Startup - Protects integrity of all upstream electrical infrastructure by staggering the inrush current draw of all plugged-in devices
  • Internal Temperature Sensor and Two Optional External Sensors - These sensors can measure environmental factors at several different points within the rack
Overview

PDUs  Rack Mount Option  Metering  Switching  Interface  Input Power  Management Interface 
PM 1000 Vertical and Horizontal Strip-level metering None Serial* or IP Single phase or three phase Avocent DSView software or on-board web interface
PM 2000 Vertical and Horizontal Outlet-level metering None Serial* or IP Single phase or three phase Avocent DSView  software or on-board web interface
PM 3000 Vertical and Horizontal Outlet-level metering Outlet-level switching Serial* or IP Single phase or three phase Avocent DSView  software or on-board web interface
PM 10 Horizontal Strip-level metering Outlet-level switching Serial* Single phase Avocent DSView  software or on-board web interface
PM 20 Vertical Strip-level metering Outlet-level switching Serial* Single phase Avocent DSView  software or on-board web interface
Direct_PDU Vertical and horizontal Strip-level metering Outlet-level switching IP Single phase On-board web interface only
Model Comparison

 

Horizontal Vertical 
Mechanical

3 and 6 outlet models:
17 x 8.272 x 1.719 in.
(43.2 x 21 x 4.4 cm)

10 outlet models:
17 x 5.5 x 1.7 in.
(43.2 x 14 x 4.3 cm)

30A/32A version of PM3000/2000
17 in x 8.3 in x 1.7 in
(43.2 x 21 x 4.3 cm)

30A/32A version of PM1000
17 in x 9.6 in x 1.7 in
(43.2 x 24.4 x 4.3 cm)

Power input cable length - 10 ft.

24 outlet models:
2.2 x 3.15 x 66 in.
(5.6 x 8 x 167.6 cm)

20 outlet models:
2.2 x 3.2 x 52 in.
(5.6 x 8.1 x 132.1 cm)

Power input cable length - 10 ft.
Weight 3 and 6 outlet models:
7.3 lbs. (without power cord)

10 outlet models:
5.2 lbs. (without power cord)
24 outlet models:
14.8 lbs.(without power cord)

20 outlet models:
11 lbs. (without power cord)
Network Connections 1- 10/100/1000 Ethernet 1- 10/100/1000 Ethernet
Serial Connections 2- (in/out for chaining purposes)
2 for external environmental sensors
2- (in/out for chaining purposes)
2 for external environmental sensors
Agency Approval UL, FCC, cUL, CE, VCCI, C-Tick, CB UL, FCC, cUL, CE, VCCI, C-Tick, CB

Note: The 20 outlet PM 1000 PDU height is 46 in. (116.8 cm)

Tech Specs

North America Models
PM 1000 Vertical Models with Strip-Level Metering

Description Part Number
PM 1000 0U Vertical 1-ph 208V 30A with L6-30, 21 C13 and 3 C19 outlets PM1001V-401
PM 1000 0U Vertical 3-ph 208V 30A with L21-30, 21 C13 and 3 C19 outlets PM1002V-401
PM 1000 0U Vertical 3-ph 208V 50A with Hubbell CS8365C, 21 C13 and 3 C19 outlets PM1003V-401
PM 1000 0U Vertical 3-ph 208V 60A with IEC309 60A, 21 C13 and 3 C19 outlets PM1004V-401
PM 1000 0U Vertical 3-ph 208V 30A with L15-30, 21 C13 and 3 C19 outlets PM1008V-401
PM 1000 0U Vertical 1-ph 30A 200 - 240V with L6-30, 20 C13 ports PM1012V-401
PM 1000 0U Vertical 1-ph 20A 100 - 240V w/IEC 320-C20 inlet, 20 C13 ports PM1014V-xxx*
PM 1000 1U Horizontal 1-ph 30A 200 - 240V with L6-30, 10 C13 ports PM1009H-401
PM 1000 1U Horizontal 1-ph 20A 100 - 240V w/IEC 320-C20 inlet, 10 C13 ports PM1011H-xxx*
*Note: Actual part number for these models ends with country-specific code and power cord type (Example -001 is used for North America and includes a L6-20 power cord) 
 
PM 2000 Models with Outlet-Level Metering
Description Part Number
PM 2000 1U Horizontal 1-ph 30A 208V, fixed cord with L6-30, 3 C19 ports PM2001H-401
PM 2000 1U Horizontal 3-ph 30A 208V, fixed cord with L15-30, 6 C19 ports PM2002H-401
PM 2000 1U Horizontal 3-ph 50A 208V, with Hubbell CS8365C, 6 C19 ports PM2005H-403
PM 2000 1U Horizontal 3-ph 60A 208V, with IEC 309 60A, 6 C19 ports PM2005H-404
PM 2000 1U Horizontal 3-ph 30A 208V, fixed cord with L21-30, 6 C19 ports PM2006H-401
PM 2000 0U Vertical 1-ph 30A 208V with L6-30, 21 C13 & 3 C19 ports PM2001V-401
PM 2000 0U Vertical 3-ph 30A 208V with L15-30, 21 C13 & 3 C19 ports PM2002V-401
PM 2000 0U Vertical 3-ph 30A 208V with L21-30, 21 C13 & 3 C19 ports PM2006V-401
PM 2000 0U Vertical 3-ph 50A 208V with Hubbell CS8365C, 21 C13 & 3 C19 ports PM2005V-403
PM 2000 0U Vertical 3-ph 60A 208V with IEC 309 60A, 21 C13 & 3 C19 ports PM2005V-404
PM 2000 1U Horizontal 1-ph 30A 200 - 240V with L6-30, 10 C13 ports PM2007H-401
PM 2000 1U Horizontal 1-ph 20A 100 - 240V w/IEC 320-C20 inlet, 10 C13 ports PM2009H-xxx*
PM 2000 0U Vertical 1-ph 30A 200 - 240V with L6-30, 20 C13 ports PM2010V-401
PM 2000 0U Vertical 1-ph 20A 100 - 240V w/IEC 320-C20 inlet, 20 C13 ports PM2012V-xxx*
*Note: Actual part number for these models ends with country-specific code and power cord type (Example -001 is used for North America and includes a L6-20 power cord)
 
PM 3000 Models with Outlet-Level Metering and Outlet-Level Switching
Description Part Number
PM 3000 1U Horizontal 1-ph 30A 208V, fixed cord with L6-30, 3 C19 ports PM3001H-401
PM 3000 1U Horizontal 3-ph 30A 208V, fixed cord with L15-30, 6 C19 ports PM3002H-401
PM 3000 1U Horizontal 3-ph 50A 208V, with Hubbell CS8365C, 6 C19 ports PM3005H-403
PM 3000 1U Horizontal 3-ph 60A 208V, with IEC 309 60A, 6 C19 ports PM3005H-404
PM 3000 1U Horizontal 3-ph 30A 208V, fixed cord with L21-30, 6 C19 ports PM3006H-401
PM 3000 0U Vertical 1-ph 30A 208V with L6-30, 21 C13 & 3 C19 ports PM3001V-401
PM 3000 0U Vertical 3-ph 30A 208V with L15-30, 21 C13 & 3 C19 ports PM3002V-401
PM 3000 0U Vertical 3-ph 30A 208V with L21-30, 21 C13 & 3 C19 ports PM3006V-401
PM 3000 0U Vertical 3-ph 50A 208V with Hubbell CS8365C, 21 C13 & 3 C19 ports PM3005V-403
PM 3000 0U Vertical 3-ph 60A 208V with IEC 309 60A, 21 C13 & 3 C19 ports PM3005V-404
PM 3000 1U Horizontal 1-ph 30A 200 - 240V with L6-30, 10 C13 ports PM3007H-401
PM 3000 1U Horizontal 1-ph 20A 100 - 240V w/IEC 320-C20 inlet, 10 C13 ports PM3009H-xxx*
PM 3000 0U Vertical 1-ph 30A 200 - 240V with L6-30, 20 C13 ports PM3010V-401
PM 3000 0U Vertical 1-ph 20A 100 - 240V w/IEC 320-C20 inlet, 20 C13 ports PM3012V-xxx*

 *Note: Actual part number for these models ends with country-specific code and power cord type (Example -001 is used for North America and includes a L6-20 power cord)

 
Cables

 

Description

Part Number
Set of 8 outlet cables: IEC320-C13 female to IEC320-C14 male
Set of 10 outlet cables: IEC320-C13 female to IEC320-C14 male ACS0046

 

 
Accessories
Description Part Number
Temperature and humidity combo sensor   PMHD-THS
Temperature only sensor PMHD-TS
 
Service Options
Description Part Number
1 YR SLV HW Maintenance PM 1YSLV-PM
2 YR SLV HW Maintenance PM 2YSLV-PM
4 YR SLV HW Maintenance PM 4YSLV-PM
1 YR GLD HW Maintenance PM 1YGLD-PM
2 YR GLD HW Maintenance PM 2YGLD-PM
4 YR GLD HW Maintenance PM 4YGLD-PM
Ordering Details
International Models
PM 1000 Vertical Models with Strip-Level Metering
 
Description Part Number
PM 1000 0U Vertical 1-ph 220/230/240V, 32A with IEC 309 32A, 21 C13 & 3 C19 PM1005V-401
PM 1000 0U Vertical 3-ph 380/400/415V, 16A with IEC 309 16A, 21 C13 and 3 C19 PM1006V-401
PM 1000 0U Vertical 3-ph 380/400/415V, 32A with IEC 309 32A, 21 C13 and 3 C19 PM1007V-401
PM 1000 0U Vertical 1-ph 32A 220/230/240V with IEC 309, 20 C13 ports  PM1013V-401
PM 1000 0U Vertical 1-ph 16A 100 - 240V w/IEC 320-C20 inlet, 20 C13 ports PM1014V-xxx*
PM 1000 1U Horizontal 1-ph 32A 220/230/240V with IEC 309, 10 C13 ports PM1010H-401
PM 1000 1U Horizontal 1-ph 16A 100 - 240V  w/IEC 320-C20 inlet, 10 C13 ports PM1011H-xxx*

*Note: Actual part number for these models ends with country-specific code and power cord type (Example -001 is used for North America and includes a L6-20 power cord)  

 
PM 2000 Models with Outlet-Level Metering
Description Part Number
PM 2000 1U Horizontal 3-ph 16A 380/400/415V, fixed cord with IEC 309 16A, 6 C19 ports PM2004H-401
PM 2000 1U Horizontal 3-ph 32A 380/400/415V with IEC 309 32A, 6 C19 ports PM2005H-406
PM 2000 0U Vertical 1-ph 32A 220/230/240V with IEC 309 32A, 21 C13 & 3 C19 ports PM2003V-401
PM 2000 0U Vertical 3-ph 16A 380/400/415v with IEC 309 16A, 21 C13 & 3 C19 ports PM2004V-401
PM 2000 0U Vertical 3-ph 32A 380/400/415V with IEC 309 32A, 21 C13 & 3 C19 ports PM2005V-406
PM 2000 1U Horizontal 1-ph 32A 220/230/240V with IEC 309, 10 C13 ports PM2008H-401
PM 2000 1U Horizontal 1-ph 16A 100 - 240V  w/IEC 320-C20 inlet, 10 C13 ports PM2009H-xxx*
PM 2000 0U Vertical 1-ph 32A 220/230/240V with IEC 309, 20 C13 ports  PM2011V-401
PM 2000 0U Vertical 1-ph 16A 100 - 240V w/IEC 320-C20 inlet, 20 C13 ports PM2012V-xxx*

*Note: Actual part number for these models ends with country-specific code and power cord type (Example -001 is used for North America and includes a L6-20 power cord)

 
PM 3000 Models with Outlet-Level Metering and Outlet-Level Switching

Description

Part Number
PM 3000 1U Horizontal 1-ph 32A 220/230/240V, fixed cord with IEC 309 32A, 3 C19 ports PM3003H-401
PM 3000 1U Horizontal 3-ph 16A 380/400/415V, fixed cord with IEC 309 16A, 6 C19 ports PM3004H-401
PM 3000 1U Horizontal 3-ph 32A 380/400/415V with IEC 309 32A, 6 C19 ports  PM3005H-406
PM 3000 0U Vertical 1-ph 32A 220/230/240V with IEC 309 32A, 21 C13 & 3 C19 ports PM3003V-401
PM 3000 0U Vertical 3-ph 16A 380/400/415v with IEC 309 16A, 21 C13 & 3 C19 port PM3004V-401
PM 3000 0U Vertical 3-ph 32A 380/400/415V with IEC 309 32A, 21 C13 & 3 C19 ports  PM3005V-406
PM 3000 1U Horizontal 1-ph 32A 220/230/240V with IEC 309, 10 C13 ports  PM3008H-401
PM 3000 1U Horizontal 1-ph 16A 100 - 240V w/IEC 320-C20 inlet, 10 C13 ports PM3009H-xxx*
PM 3000 0U Vertical 1-ph 32A 220/230/240V with IEC 309, 20 C13 ports  PM3011V-401
PM 3000 0U Vertical 1-ph 16A 100 - 240V w/IEC 320-C20 inlet, 20 C13 ports PM3012V-xxx*

*Note: Actual part number for these models ends with country-specific code and power cord type (Example -001 is used for North America and includes a L6-20 power cord)  

 
Cables
Description Part Number
Set of 8 outlet cables: IEC320-C13 female to IEC320-C14 male ACS0040
Set of 10 outlet cables: IEC320-C13 female to IEC320-C14 male  ACS0046
 
Accessories
Description Part Number
Temperature and humidity combo sensor   PMHD-THS
Temperature only sensor PMHD-TS
 
Service Options
Description Part Number
1 YR SLV HW Maintenance PM 1YSLV-PM
2 YR SLV HW Maintenance PM 2YSLV-PM
4 YR SLV HW Maintenance PM 4YSLV-PM
1 YR GLD HW Maintenance PM 1YGLD-PM
2 YR GLD HW Maintenance PM 2YGLD-PM
4 YR GLD HW Maintenance PM 4YGLD-PM
Order Details-Int'l