Liebert IntelliSlot Web Card Communications Interface Card


PRODUCTS


Liebert IntelliSlot Web Card Communications Interface Card

Emerson Network Power > Products > Monitoring > For Large Data Center > Advanced Monitoring > Liebert IntelliSlot Web Card Communications Interface Card
Liebert IntelliSlot Web Card family delivers SNMP, Telnet and web-management capability for enhanced communications and control of Liebert UPS, Power Management or Precision Cooling systems. The card manages a wide range of operating parameters, alarms and notifications, transmitting data over the network.

Liebert IntelliSlot Web Card (formerly Liebert OpenComms Web Card and Liebert OpenComms NIC Card) delivers SNMP and Web management to a Liebert UPS, Power Management or Precision Cooling system connected to any 10- or 100-Mbit Ethernet network. The interface provides for remote web or in-the-field firmware upgrade. Alarms and parameters are transmitted over the network using SNMP, email, and SMS text. In addition, Liebert IntelliSlot Web Card w/Adapter supports Modbus.

  • Liebert IntelliSlot Web Card is compatible with the Liebert PowerSure PSI line-interactive UPS, Liebert GXT on-line UPS, Liebert GXT 6 & 10kVA on-line UPS, Liebert GXT 2U on-line UPS and Liebert Nfinity on-line UPS.
  • Liebert IntelliSlot Web Card LB is compatible with Liebert NX on-line UPS and Liebert Hinet on-line UPS.
  • Liebert IntelliSlot Web Card LBDS is compatible with Liebert DS and Liebert XDF precision cooling systems.
  • Liebert IntelliSlot Web/485 Card ADPT is compatible with Liebert Power, UPS and Precision Cooling systems that are not equipped with an IntelliSlot port.
  • Liebert IntelliSlot 485 NXL card is compatible with Liebert NXL on-line UPS.
  • Liebert IntelliSlot Web Card L card is compatible with Liebert iCOM v.4 for all Liebert XDP iCOM, Liebert CRV and FW - PA1.04.033.STD or later for the Liebert DS, Liebert Challenger, and Liebert Deluxe.
  • Liebert IntelliSlot Web Card IPBML is compatible with Liebert iCOM v.4 for all Liebert XDP iCOM, Liebert CRV and FW - PA1.04.033.STD or later for the Liebert DS, Liebert Challenger, and Liebert Deluxe.
  • Liebert IntelliSlot Web Card S is compatible with Liebert PPC.
  • Liebert IntelliSlot Web Card IPBMS is compatible with Liebert PPC.
Product Downloads
Multi-Media
 
Features
  • Web interface card with SNMP and Telnet capability
  • Provides alarm notifications via email and text messaging
  • Monitors UPS parameters via web browser
  • Operates compatibly with Liebert monitoring software
Benefits

Flexibility

  • Allows systems to be viewed from the network using a web browser.
  • Delivers SNMP, Telnet and web management.
  • Provides security using HTTPS message encryption.
  • Supports 10- and 100-MBit Ethernet for legacy and modern networks.

Higher Availability

  • Provides compatibility with Liebert MultiLink shutdown software, to prevent data loss and ensure data availability.
  • Supports Liebert SiteScan WEB enterprise monitoring software, to provide trending for proactive analysis and maintenance to ensure facility uptime.
  • Interfaces to Liebert Nform alarm notification software, to facilitate quick corrective action.

Lowest Total Cost Of Ownership

  • Allows use of existing network, saving the cost of dedicated wiring.
  • Requires no additional software installation for basic monitoring.
  • Provides notification in the absence of a comprehensive monitoring system.
  • Provides a single point of information/control.

Ideally Suited For

  • Small and large data centers
  • Computer rooms, network access spaces or server closets
  • Telecommunications facilities
  • Industrial process control centers
  • Other sensitive electronic applications
Product FAQs

Can I obtain a list of the supported SNMP Traps and parameters from the card?

Yes, on the Support Tab of the Web interface is the SNMP capabilities Information (i.e. Traps/Events, Parameters). In addition, this information is available via the serial connection and Telnet. Consult the User Manual for more details.

How many SNMP Trap targets can I configure in the Liebert IntelliSlot Web Card?

20

Is the Liebert IntelliSlot Web Card hot-swappable?

Yes, you will not be required to shutdown your UPS to install this card.

What is the default User Name and Password for the Liebert IntelliSlot Web Card?

User Name: Liebert
Password: Liebert

What Liebert products are supported by the IS-WEBCARD?

Liebert PowerSure PSI line-interactive UPS, Liebert GXT on-line UPS, Liebert GXT 6 & 10kVA on-line UPS, Liebert GXT 2U on-line UPS and Liebert Nfinity on-line UPS

What Liebert products are supported by the IS-WEBLB?

Liebert NX on-line UPS and Liebert Hinet on-line UPS.

Where can I obtain a user manual for my Liebert IntelliSlot Web Card?

http://www.emersonnetworkpower.com/en-CA/Products/Monitoring/ForLargeDataCenter/AdvancedMonitoring/Pages/LiebertIntelliSlotWebCardCommunicationsInterfaceCard.aspx

Where can I view and test drive the web interface for the product I am purchasing?

http://demos.liebert.com/

Software Download

Liebert IntelliSlot, Web Card Interface MIBs
For all devices and operating systems

Firmware

 Firmware OCWEBCARD HID3 2.400.3 (R 06/10)
OC-WEB Card found in small UPS units
 Firmware IS-WEBCARD HID6 3.100.3 (R 06/10)
IS-WEB Card found in small UPS units
 Firmware IS-WEBCARD HID9 5.00.1 (03/11)
IS-WEB Card found in small UPS units
 Firmware RPC_HID16_4.840_062878 (07/11)
RPC Card found in MPX and MPH rack PDUs
 Firmware IS-WEBLBDS HID7 3.210
IS-WEB Card found in Liebert DS air units
 Firmware OCNIC_REV2_BLD94
OpenComms NIC and NIC-485, running version 2.x
 Firmware OCWEB-ADPT_HID5_3_121_1 (01/10)  
OCWEB Adapter found in large Air, UPS and Power units, running version 3.x
 Firmware IS-WEBLB HID7 3.310.3  (R 06/10)
IS-WEBLB Card found in NX UPS units
 Firmware IS-WEBLB_HID10_5.010.1 (06/10)
IS-WEBLB Card found in NX UPS units
 Firmware IS-IPBML _HID10_5.0E0.1_060114 (11/10)
IS-IPBML Bacnet and Modbus IP Card found in large units
 Firmware IS-485L_HID12_5.190.0_057224 (06/10)   
485 Modbus Card found in large units
 Firmware IS-WEBL_HID10_5.180.0_058784 (08/10)
IS-WEBL Card found in large units
 Firmware OC485-LBDS-FW_REV1 (R 3/08)
 Firmware OCWEB-LBDS HID5 3.210.0 (R04/09)

MIBS

 MIB for Unix Based Systems 192435P1 REV 3
 MIB for Windows Based Systems 192436P1 REV 3

Contact Support

Monitoring products
Contact our Liebert NA support department about your Liebert monitoring software and hardware.

Sales, Service and Support
1-800-222-5877
Outside the U.S:  +800-1155-4499
 
Monitoring products
Contact our Liebert support department about your monitoring software and hardware

 
Data Center Assessment
Learn how to identify and resolve data center issues
Learn more