Emerson | Firetrol FTA200 A Alarm Panels


Firetrol FTA200 A Alarm Panels

Remote Alarm Panel

Emerson Network Power > ASIA > Products > By Type > Fire Pump Controllers > Alarm Panels > Firetrol FTA200 A Alarm Panels
Firetrol® FTA200 alarm panels are designed to meet the NPFA 20 specifications requiring a remote alarm panel when the pump house or pump room is not constantly attended. The alarm panel must be installed in a location that is under supervision at all times.
These alarm panels are listed by Underwriter’s Laboratories, Inc., in accordance with UL508, Standard for Industrial Controls, certifi ed by CSA, Standard for Industrial Control Equipment (cUL) and approved by Factory Mutual. They are designed to meet or exceed the requirements of the approving authorities listed above as well as NFPA 20, Installation of Centrifugal Fire Pumps.
The standard enclosures are NEMA Type 2 (IEC IP11), drip-proof for indoor wall mounting. The standard enclosure color is red.

The following are included as standard as shown with each alarm panel type:

Type A — Designed for use with electric motor driven fire pump controllers, they provide indication for the following conditions:

  • Supervisory Voltage Normal (Audible & Visible)
  • Pump Operating (Audible & Visible)
  • Pump Phase Failure (Audible & Visible)
  • Pump Phase Reversal (Audible & Visible)

FTA200 alarm panels make use of printed circuit boards which provide reliable and trouble free service.

Mounted on the enclosure door are the pilot lights for visible alarm indication, the audible device for audible alarm indication, the SILENCE ALARM push-button and the PUSH-TO-TEST push-button.

Each pilot light will illuminate to indicate its alarm condition and will remain lighted until the abnormal condition has been corrected. The audible alarm will sound when the alarm conditions occur and will continue to sound until the abnormal condition has been corrected or the SILENCE ALARM push-button has been pressed. Pressing the SILENCE ALARM push-button will silence the audible alarm but will not extinguish the pilot light. If another alarm condition occurs, the audible alarm will again sound until silenced by the SILENCE ALARM push-button or until the abnormal condition has been corrected.

The PUSH-TO-TEST push-button is supplied for manually testing the pilot lights, audible alarm and output circuits.


Special Enclosures
-F NEMA Type 4X, 304 stainless (IEC IP56)
-Y NEMA Type 1 (IEC IP10) Flush Mount Painted Steel
Consult Factory for other style enclosures.
Standard Remote Alarms
-AM Pump Fail To Start
-BY Pump Overload
-EG Relief Valve Discharge
-EJ Flow Meter On
Non-Standard Remote Alarms

When ordering, specify the number of alarms required, the function of each and the nameplate marking of each.

-LA Substitute Amber for Red Pilot Lights. To meet local code requirements.
-BA Operation on 220-240 Volts. Panel is supplied as standard for operation on 110-120 volts.
-BS “Pump Start” Pushbutton. Mounted on enclosure door.