Liebert GXT-MT Plus 1-3kVA

 
PRODUCTS​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​​

Liebert GXT-MT Plus 1-3kVA
Compact Tower UPS for High Performance Power Protection

 Liebert GXT MT Plus Data Sheet

This product is available only in Hong Kong, Indonesia, Malaysia, Philippines, Singapore, Thailand and Vietnam

Emerson Network Power > ASIA > Products > By Type > AC Power and UPS > Network UPS > Liebert GXT-MT Plus 1-3kVA

The Liebert GXT MT+ features best-in-class power protection for critical applications with the use oftrue on-line double conversion technology. The Liebert GXT MT+ has a comprehensive specification that provides a higher level of availability to the IT equipment. It satisfies safety criteria and electromagnetic compatibility standards while offering intelligent monitoring and network management functions. This high performance UPS with proven reliability is available in a compact tower design.

Brochures and Data Sheets
 
Manuals
 
Product Downloads
  • Double conversion on-line technology
  • Compact tower design
  • Standard models and long backup models available
  • Extended runtime capabilities by building up additional battery resources
  • Flexible (site specific) battery configuration
  • Standard model comes with internal battery
  • Generator-compatible with wide input frequency range (40 to 70 Hz)
  • 0.8 output power factor
  • Class A electromagnetic interference (EMC)
  • Ultra wide input voltage range
  • High input power factor & low THDi
  • Emergency power off (EPO)
  • Configurable to energy saving mode (ECO)
  • LCD display for operational convenience and status / fault information
  • Multiple AC output interfaces via IEC standard sockets with Programmable output
  • Remote Monitoring is available through USB / RS232, and optional via dry contacts and SNMP
Features

The Liebert GXT-MTPlus is ideally suited for:    

  • Small Size Data Center
  • Telecommunication Equipment
  • VoIP
  • Small Offi ce Network
  • Computer Rooms
  • Process Automation Equipment
  • Network Storage Devices

What's in the box?

  • UPS Module
  • Battery Connection Cable only with Long Backup models
  • RS 232 Cable / USB Cable
  • UPS Monitoring Software (to be downloaded from internet)
  • User Manual
  • IEC Output cables x 2
  • CEE7/7 to IEC-C20 and BS1363 to IEC-C20 input power cord (3KVA model
Benefits
What is the Liebert GXT-MTPlus? 
  • Liebert GXT-MTPlus is the latest on-line UPS of Emerson Network Power for servers and network devices, available in 230V.

What shutdown software is compatible with Liebert GXT-MTPlus?

  • The new Liebert GXT-MTPlus requires ViewPower shutdown software.

What Operation System can ViewPower Support?

  • Windows 2000
  • Windows 2003
  • Windows XP
  • Windows Vista
  • Windows 2008 (32-bit and x64-bit)
  • Windows 7 (32-bit and x64-bit)
  • Redhat Linux 8 and above
  • Redhat Enterprise AS3 and above
  • Suse Linux 10 and above
  • Ubuntu 6.1 and above
  • Fedora 5 and above
  • Linux server: Redhat Enterprise Linux AS5, Suse Linux 10
  • Linux DesktopL Ubuntu Linux 8.1
  • MacOSX 10 and above
  • MacOS 8, 9
  • Solaris 8, 9, 10

What is the warranty period of Liebert GXT-MTPlus?

  • Standard micro UPS warranty (usually 2 years) applies.
FAQs

Part Number

Standard
Model

GXT-1000MTPLUS230

GXT-2000MTPLUS230

GXT-3000MTPLUS230

Long
Backup Model

GXT-1000LMTPLUS230

GXT-2000LMTPLUS230

GXT-3000LMTPLUS230

Capacity (VA/W)

1000 / 800

2000/1600

3000/2400

Input Parameters

Frequency Range

40Hz ~ 70 Hz

Phase

Single phase with ground

Power Factor

≥ 0.99 @ 220 to 230 VAC (input voltage)

Voltage Range

Low Line Transfer

160 VAC / 140 VAC / 120 VAC / 110 VAC ± 5 %
( based on load percentage 100% - 80 % / 80 % - 70 % / 70 - 60 % / 60 % - 0)

Low Line Comeback

175 VAC ± 5 %

High Line Transfer

300 VAC ± 5 %

High Line Comeback

290 VAC ± 5 %

Output Parameters

Output Voltage

208/220/230/240VAC

AC Voltage Regulation

± 3% (Batt. Mode)

Frequency Range

47 to 53 Hz or 57 to 63 Hz (Synchronized Range)

Frequency Range (Batt. Mode)

50 Hz ± 0.25Hz

Overload

100% to 110%: audible warning
110% to 130%: UPS shuts down in 30 seconds at battery mode or transfers to bypass mode when the utility is normal.
>130%: UPS shuts down immediately at battery mode or transfer to bypass mode when the utility is normal.

Current Crest Ratio

3:1

Harmonic Distortion

≤ 3 % THD (Linear Load)
≤ 4 % THD (Linear Load)

≤ 6 % THD (Non-linear Load)
≤ 7 % THD (Non-linear Load)

Waveform (Batt. Mode)

Pure Sinewave

Efficiency

AC Mode

~ 85%

~ 88%

Battery Mode

~ 83%

Transfer Time

AC Mode to Batt. Mode

Zero

Inverter to Bypass

4 ms (Typical)

Battery Charger (Standard Model)

Battery Type

12 V / 7 AH

12 V /7 AH

12 V / 9 AH

Numbers

3

6

6

Typical Recharge Time

4 hours recover to 90% capacity (Typical)

Charging Current

1.0 A(max.)

Charging Voltage

41.0 VDC ± 1%

82.1 VDC ±1%

Battery Charger (Long back-up Model)

Numbers

3

8

Charging Current

4.0 A or 8.0 A(max.)

Charging Voltage

41.0 VDC ± 1%

109.6 VDC ±1%

Physical Parameters

Dimension, D X W X H

220 x 145 x 397

318 x 190 x 421

Net Weight (kgs)

13

7

26

13

28

13

Emvironmental Parameters

Operation Humidity

20 to 90 % RH @ 0 to 40°C (non-condensing)

Noise Level

Less than 55dBA @ 1 Meter

Management

Smart RS-232 or USB

Supports Windows 98/2000/2003/XP/Vista/2008/ 7, Linux, and MAC

Optional SNMP

Power management from SNMP manager and web browser

 

Technical Specifications

 